m+Medelevator.RU
← Поиск публикаций
Investigative and clinical urology · 2025

Comparative efficacy and safety of energy coagulation in radiation-induced hemorrhagic cystitis: A narrative review.

СтатьяОбзорСравнительное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Khern Wei Chern, Rajandram Retnagowri, Raja Ram Novinth Kumar, Kuppusamy Shanggar

Аннотация

To assess the efficacy and safety of using energy devices as treatment for radiation-induced hemorrhagic cystitis (RHC) and to determine the most suitable energy source, settings and techniques based on laser-tissue interaction. A search of Google Scholar, PubMed, and Web of Science databases was conducted uptil February 2024 to identify studies on use of energy devices for RHC. Additionally, ClinicalTrials.gov and the World Health Organization's ICTRP (International Clinical Trials Registry Platform) were searched for ongoing studies. We identified 10 studies fulfilling the search criteria using modalities including Nd:YAG laser, argon plasma coagulation, 980-nm diode laser, and potassium-titanyl-phosphate (KTP) laser. Across studies (n=137), majority (n=116, 84.7%) of RHC patients achieved hematuria resolution after one treatment session, with mean/median hematuria-free intervals of 11 to 16 months. Six patients (4.4%) were unresponsive and underwent cystectomy/urinary diversion. Total adverse events occurred in patients (30/139, 21.6%), including storage symptoms, recurrent hematuria, bladder stones and urinary retention, among others. Typical laser settings involved low power (<40 W), with either a pulse duration of 2-3 seconds or 10-40 milliseconds; some used continuous wave mode. Other standard practises include selective coagulation employed in a "painting" fashion and non-contact mode (3-5 mm). The treatment endpoints were hemostasis, involution of telangiectatic vessels and formation of pale well-circumscribed mucosal ulcer. Energy devices have considerable efficacy and safety to treat RHC patients and can be considered for refractory RHC and as an adjunct after initial management. The various properties of KTP laser confers an advantage over other energy devices.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты