Avidin-Functionalized Gold Nanoparticles Enable Cationic Isotachophoresis for Enhanced Lateral Flow Assays.

McCornack Devon, Ivory Cornelius F, Zhang Zhihong, Dong Wen-Ji

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Lateral flow assays (LFAs) are widely used for rapid, point-of-care diagnostics but struggle with sensitivity in part due to passive migration and interference from high-abundance serum proteins. Here, we introduce the lateral isotachophoresis-guided migration analysis (LIGMA) assay, a novel diagnostic platform that leverages cationic isotachophoresis (+ITP) to enhance biomolecular separation and detection in LFAs. Using avidin-functionalized gold nanoparticles (AV-S-GNPs) as positively charged nanocarriers, this system enables the direct electrophoretic migration of negatively charged analytes, overcoming a major limitation of conventional cationic electrokinetic focusing methods. The functionalized nanoparticles exhibited superior stability across physiological pH ranges and maintained consistent electrophoretic mobility under + ITP conditions. LIGMA achieved a limit of detection of 1.97 nM and a limit of quantification of 4.12 nM for human immunoglobulin G (IgG), requiring only 1 μL of sample volume and under 2 min of assay time. Compared to standard LFAs, ITP-enhanced migration produced sharper capture line resolution, improved analyte focusing, and minimized background interference from abundant serum proteins. This work establishes the LIGMA assay as a viable electrokinetic strategy for improving paper-based biosensors, providing a foundation for expanded applications in clinical diagnostics, multiplexed detection, and portable field-deployable biosensing platforms.

Для цитирования: McCornack Devon, Ivory Cornelius F, Zhang Zhihong, Dong Wen-Ji. Avidin-Functionalized Gold Nanoparticles Enable Cationic Isotachophoresis for Enhanced Lateral Flow Assays.. Analytical chemistry. 2026. DOI: 10.1021/acs.analchem.6c00357.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.