DOI 10.1016/j.acap.2019.09.006
Medication Errors From Over-the-Counter Cough and Cold Medications in Children.
Аннотация
OBJECTIVE
Out of hospital medication-related adverse events (AEs) from cough and cold medications (CCMs) can have significant public health impact. The objective of this study was to characterize pediatric medication error AEs involving over-the-counter (OTC) CCMs to identify preventable factors.
METHODS
Multisource national data surveillance system study using an expert panel evaluating CCM AEs related to medication errors.
INCLUSION CRITERIA: age <12 years, and at least 1 significant AE from at least 1 index ingredient from a CCM OTC product.
RESULTS
From 2009 through 2016, 4756 cases were determined to have a significant AE related to an OTC CCM ingredient and 513 (10.8%) cases were due to a medication error. Nearly half of medication errors involved children 2 to <6 years old (n = 235; 45.8%). Many involved administration by a parent (n = 231; 45.0%) or alternative caregiver (n = 148; 28.8%). In nearly all cases (93.2%), the medication error involved the wrong dose of the medication. Health care facility evaluation occurred in 381 (74.3%) cases. Diphenhydramine and dextromethorphan were responsible for most medication errors and medication errors involving health care facility evaluation. There were no deaths from medication errors.
CONCLUSION
In this multiyear surveillance study, medication errors most commonly occurred in children <6 years old who received the wrong volume of a liquid product. Diphenhydramine and dextromethorphan dosing errors were the most common cause of medication errors resulting from CCM use. Continued standardization of measuring devices, concentrations, and units of measure along with consumer education are needed to further decrease medication errors from CCMs.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.