MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/rct.0000000000000093

Медицинская библиотека · Journal of computer assisted tomography · 2014

Minor ossicular anomalies in the middle ear: role of submillimeter multislice computed tomography.

Nakasato Tatsuhiko, Nakayama Tetsuo, Nakayama Manabu, Ehara Shigeru, Ohtsuka Hisashi, Sato Hiroaki

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The objective was to elucidate clinical effectiveness of submillimeter multislice 2- and 3-dimensional computed tomography (CT) for diagnosis of congenital middle ear anomaly.

MATERIALS AND

METHODS

Preoperative CT and operative findings were retrospectively analyzed in 36 ears of 33 patients. The distance between the malleal handle (MH) and the incus long process (ILP) was measured in 28 normal ears.

RESULTS

Mean ± SD MH-ILP distance in normal ears was 1.8 ± 0.3 mm. In patients with middle ear anomaly, overall specificity, accuracy, and positive and negative predictive values were 99.7%, 98.7%, 91.7%, and 99.1%, respectively. Overall sensitivity was 82.1%, with relatively low sensitivities for detecting fused incudomalleolar joint, lenticular process defect, stapedial footplate defect, and oval window atresia and high sensitivities (80%-100%) for stapedial crural anomaly and certain fibrous connections.

CONCLUSIONS

Submillimeter CT improved detectability of anomalies of the stapedial superstructure; however, it is still difficult to identify abnormalities of the footplate.

Для цитирования: Nakasato Tatsuhiko, Nakayama Tetsuo, Nakayama Manabu, Ehara Shigeru, Ohtsuka Hisashi, Sato Hiroaki. Minor ossicular anomalies in the middle ear: role of submillimeter multislice computed tomography.. Journal of computer assisted tomography. 2014. DOI: 10.1097/rct.0000000000000093.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.