MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2023.131381

Медицинская библиотека · International journal of cardiology · 2023

ICD outcome in pediatric arrhythmogenic cardiomyopathy.

Cicenia Marianna, Silvetti Massimo Stefano, Cantarutti Nicoletta, Battipaglia Irma, Adorisio Rachele, Saputo Fabio Anselmo, Tamburri Ilaria, Campisi Marta, Baban Anwar, Drago Fabrizio

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Arrhythmogenic cardiomyopathy (ACM) is a very rare condition among pediatric patients. Sudden cardiac death (SCD) is the main complication and often requires ICD implantation. Aim of the study is the evaluation of the outcomes of ICD implanted ACM pediatric patients in terms of safety, efficacy and complications.

METHODS

All pediatric patients (<18 y.o.) diagnosed with ACM and who were implanted with ICD since 2009 in Our Institution were collected. Implantation was decided according to current recommendations/ guidelines, and outcome was recorded during follow-up.

RESULTS

Nineteen consecutive ACM patients were implanted with ICD. Subcutaneous ICDs (S-ICD) were implanted in 15 patients (79%) while transvenous ICDs (TV-ICD) in 4 patients (21%). Mean age at implantation was 14.3 ± 2.1 y.o. ICDs were implanted for secondary prevention in 4 (21%) patients, and for primary prevention in 15 (79%). During the follow-up (5.59 ± 3.4 years), appropriate ICD interventions were delivered in 4 (21%) patients for sustained VTs, [2 implanted in primary prevention (13%) and 2 in secondary prevention (50%)]. No defibrillation failures occurred. Inappropriate shocks occurred in 2 cases (10.5%). Device-related complications requiring device revision occurred in 3 (16%): lead dislodgement, surgical skin erosion and sensing defect.

CONCLUSIONS

In a pediatric ACM cohort, appropriate ICD therapies occurred in a minority of primary prevention patients and frequently in secondary prevention patients. The rate of inappropriate shocks and device-related complications were even more rare and mostly wound related. Therefore, ICD therapy in pediatric ACM is effective and safe.

Для цитирования: Cicenia Marianna, Silvetti Massimo Stefano, Cantarutti Nicoletta, Battipaglia Irma, Adorisio Rachele, Saputo Fabio Anselmo, Tamburri Ilaria, Campisi Marta, Baban Anwar, Drago Fabrizio. ICD outcome in pediatric arrhythmogenic cardiomyopathy.. International journal of cardiology. 2023. DOI: 10.1016/j.ijcard.2023.131381.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.