DOI 10.1007/s00381-023-05987-0
That which is unseen: 3D printing for pediatric cerebrovascular education.
Аннотация
INTRODUCTION
Pediatric cerebrovascular lesions are very rare and include aneurysms, arteriovenous malformations (AVM), and vein of Galen malformations (VOGM).
OBJECTIVE
To describe and disseminate a validated, reproducible set of 3D models for optimization of neurosurgical training with respect to pediatric cerebrovascular diseases
METHODS
All pediatric cerebrovascular lesions treated at our institution with adequate imaging studies during the study period 2015-2020 were reviewed by the study team. Three major diagnostic groups were identified: aneurysm, AVM, and VOGM. For each group, a case deemed highly illustrative of the core diagnostic and therapeutic principles was selected by the lead and senior investigators for printing (CSG/JM). Files for model reproduction and free distribution were prepared for inclusion as Supplemental Materials.
RESULTS
Representative cases included a 7-month-old female with a giant left MCA aneurysm; a 3-day-old male with a large, complex, high-flow, choroidal-type VOGM, supplied from bilateral thalamic, choroidal, and pericallosal perforators, with drainage into a large prosencephalic vein; and a 7-year-old male with a left frontal AVM with one feeding arterial vessel from the anterior cerebral artery and one single draining vein into the superior sagittal sinus
CONCLUSION
Pediatric cerebrovascular lesions are representative of rare but important neurosurgical diseases that require creative approaches for training optimization. As these lesions are quite rare, 3D-printed models and open source educational materials may provide a meaningful avenue for impactful clinical teaching with respect to a wide swath of uncommon or unusual neurosurgical diseases.