MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41390-022-02321-3

Медицинская библиотека · Pediatric research · 2022

Perfused boundary region as biomarker for endothelial integrity in former preterms in adolescence.

Van Loo Liselotte, Allegaert Karel, Levtchenko Elena, Zhang Zhenyu, Staessen Jan A, Raaijmakers Anke

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Extremely low birth weight (ELBW) survivors have microvascular structural differences already described in kidney and retina, suggesting changes in endothelial integrity. A biomarker of endothelial integrity is perfused boundary region (PBR), which measures glycocalycal thickness. The endothelial glycocalyx is a complex, highly versatile structure with essential roles in vascular integrity and function. We explored PBR patterns together with other microvascular markers in healthy controls and former ELBW children.

METHODS

In the PREMATCH cohort (87 healthy controls, 93 ELBW survivors), we assessed endothelial integrity by calculating PBR (sidestream dark-field imaging), several microvascular markers (blood pressure, estimated glomerular filtration rate (eGFRcysC)), and retinal imaging in early adolescence. We explored differences between both groups, and searched for perinatal determinants of PBR and correlations between different microvascular markers.

RESULTS

We provided reference values for PBR (average 1.90 µm, SD 0.30) in children. PBR was not different from ELBW survivors during early adolescence, despite their higher blood pressure, lower eGFRcysC, and different retinal vessel width and tortuosity.

CONCLUSIONS

We generated reference values for PBR in early adolescence. Despite some correlations between microvascular parameters, there seem to be numerous confounders to propose PBR as a marker for endothelial integrity in ELBW survivors.

IMPACT: The endothelial glycocalyx is a complex and versatile structure. Changes in blood pressure and retinal and renal vascularization suggest a disturbance of its integrity in extremely low birth weight (ELBW) survivors. Its thickness can be measured by calculating perfused boundary region (PBR) using sidestream dark-field imaging, with a higher PBR indicating a thinner glycocalyx. We generated reference values for PBR in healthy adolescents. These values were not different in former ELBW children. Despite some correlations of PBR with other microvascular biomarkers, these are not strong enough to describe endothelial integrity and its covariates in former ELBW children.

Для цитирования: Van Loo Liselotte, Allegaert Karel, Levtchenko Elena, Zhang Zhenyu, Staessen Jan A, Raaijmakers Anke. Perfused boundary region as biomarker for endothelial integrity in former preterms in adolescence.. Pediatric research. 2022. DOI: 10.1038/s41390-022-02321-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.