MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0218492316648584

Медицинская библиотека · Asian cardiovascular & thoracic annals · 2016

Obturator foramen bypass for infective groin caused by closure device.

Irie Yoshihito, Kondo Shunichi, Rokkaku Kyu, Tsuboi Eitoshi, Takano Hiroshi, Yokoyama Hitoshi

Клинический случайСтатьяПеревод в очереди

Аннотация

A 69-year-old man underwent carotid artery stenting through the right femoral artery with a percutaneous vascular closure device for hemostasis. Eleven days later, an infective femoral artery pseudoaneurysm was diagnosed by computed tomography. At surgery, a defect in the femoral artery was observed, corresponding to the remnants of the closure device. Removal of the foreign material, debridement, wound irrigation, and arterial patch plasty were performed, but the infection and leg ischemia did not improve. After several failed attempts to revascularize and control the infection, obturator foramen bypass was performed. The postoperative course was uneventful, indicating the usefulness of this procedure.

Для цитирования: Irie Yoshihito, Kondo Shunichi, Rokkaku Kyu, Tsuboi Eitoshi, Takano Hiroshi, Yokoyama Hitoshi. Obturator foramen bypass for infective groin caused by closure device.. Asian cardiovascular & thoracic annals. 2016. DOI: 10.1177/0218492316648584.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.