MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1515/cclm-2025-0022

Медицинская библиотека · Clinical chemistry and laboratory medicine · 2025

A novel immunoprecipitation-based targeted liquid chromatography-tandem mass spectrometry analysis for accurate determination for copeptin in human serum.

Mu Danni, Ma Xiaoli, Ma Yichen, Wang Danchen, Zou Yutong, Zhu Ying, Zhong Jian, Sun Dandan, Yin Yicong, Gao Yumeng, Li Yuemeng, Chen Shi, Zhu Huijuan, Yu Songlin, Qiu Ling, Cheng Xinqi

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

Copeptin, a stable and simple-to-measure surrogate marker for arginine vasopressin (AVP), demonstrates excellent clinical values, particularly in diagnosing polyuria-polydipsia syndromes. However, conventional immunoassay methods are limited and lack comparability. Our aim was to establish a targeted liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying copeptin in human serum.

METHODS

Copeptin was extracted from serum using immunoprecipitation, digested with trypsin, and prepared using anion exchange solid-phase extraction before LC-MS/MS detection. The analytical performance was validated in accordance with current guidelines. The method was compared to an immunofluorescent assay on the B.R.A.H.M.S platform.

RESULTS

The LC-MS/MS method had a runtime of 8.5 min. The within-run precision ranged from 5.2 to 12.1 %, and total coefficients of variation ranged from 8.1 to 13.5 %. Copeptin quantitation showed linearity within the range of 5-1,000 pg/mL, with a limit of detection of 2.5 pg/mL. Recovery rates ranged from 95.2 to 103.1 %, and no significant matrix effect was observed with internal standard correction. The LC-MS/MS method had a good consistency with the immunoassay (r=0.926, slope=0.989). The reference interval for healthy individuals was 3.66-58.25 pg/mL.

CONCLUSIONS

We demonstrated the accuracy and reliability of this targeted LC-MS/MS method for quantifying copeptin. This innovative application showed satisfactory precision, a wide linear range, and a low limit of detection. Clinical studies are anticipated to be conducted to assess diagnostic accuracy using this method.

Для цитирования: Mu Danni, Ma Xiaoli, Ma Yichen, Wang Danchen, Zou Yutong, Zhu Ying, Zhong Jian, Sun Dandan, Yin Yicong, Gao Yumeng, Li Yuemeng, Chen Shi, Zhu Huijuan, Yu Songlin, Qiu Ling, Cheng Xinqi. A novel immunoprecipitation-based targeted liquid chromatography-tandem mass spectrometry analysis for accurate determination for copeptin in human serum.. Clinical chemistry and laboratory medicine. 2025. DOI: 10.1515/cclm-2025-0022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.