MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/21501351221079523

Медицинская библиотека · World journal for pediatric & congenital heart surgery · 2022

Early Outcomes of Patients Undergoing Neoaortic Valve Repair Incorporating Geometric Ring Annuloplasty.

Kupferschmid John P, Turek Joseph W, Hughes G Chad, Austin Erle H, Alsoufi Bahaaldin, Smith J Michael, Scholl Frank G, Rankin J Scott, Badhwar Vinay, Chen Jonathan M, Nuri Muhammad A, Romano Jennifer C, Ohye Richard G, Si Ming-Sing

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

During congenital heart surgery, the pulmonary valve and root may be placed into the systemic position, yielding a "neoaortic" valve. With the stress of systemic pressure, the pulmonary roots can dilate, creating aneurysms and/or neoaortic insufficiency (neoAI). This report analyzes the early outcomes of patients undergoing neoaortic valve repair incorporating geometric ring annuloplasty.

METHODS

Twenty-one patients underwent intended repair at six centers and formed the study cohort. Thirteen had previous Ross procedures, five had arterial switch operations, and three Fontan physiology. Average age was 21.7 ± 12.8 years (mean  ±  SD), 80% were male, and 11 (55%) had symptomatic heart failure. Preoperative neoAI Grade was 3.1  ±  1.1, and annular diameter was 30.7  ±  6.5 mm.

RESULTS

Valve repair was accomplished in 20/21, using geometric annuloplasty rings and leaflet plication (n = 13) and/or nodular release (n = 7). Fourteen had neoaortic aneurysm replacement (13 with root remodeling). Two underwent bicuspid valve repair. Six had pulmonary conduit changes, one insertion of an artificial Nodulus Arantius, and one resection of a subaortic membrane. Ring size averaged 21.9  ±  2.3 mm, and aortic clamp time was 171  ±  54 minutes. No operative mortality or major morbidity occurred, and postoperative hospitalization was 4.3  ±  1.4 days. At discharge, neoAI grade was 0.2  ±  0.4 (P < .0001), and valve mean gradient was ≤20 mm Hg. At average 18.0  ±  9.1 months of follow-up, all patients were asymptomatic with stable valve function.

CONCLUSIONS

Neoaortic aneurysms and neoAI are occasionally seen late following Ross, arterial switch, or Fontan procedures. Neoaortic valve repair using geometric ring annuloplasty, leaflet reconstruction, and root remodeling provides a patient-specific approach with favorable early outcomes.

Для цитирования: Kupferschmid John P, Turek Joseph W, Hughes G Chad, Austin Erle H, Alsoufi Bahaaldin, Smith J Michael, Scholl Frank G, Rankin J Scott, Badhwar Vinay, Chen Jonathan M, Nuri Muhammad A, Romano Jennifer C, Ohye Richard G, Si Ming-Sing. Early Outcomes of Patients Undergoing Neoaortic Valve Repair Incorporating Geometric Ring Annuloplasty.. World journal for pediatric & congenital heart surgery. 2022. DOI: 10.1177/21501351221079523.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.