DOI 10.1007/s00417-024-06557-z
IOL calculation using six formulas in children undergoing lens extraction and primary IOL implantation with and without posterior optic capture.
Аннотация
PURPOSE: To evaluate formulas for intraocular lens (IOL) calculation in children undergoing lens extraction and IOL implantation.
METHODS
Retrospective, consecutive case series at the Department of Ophthalmology, Goethe University Frankfurt, Germany. We included eyes that received lens extraction and IOL implantation (SN60AT, Alcon, Fort Worth, TX) due to congenital or juvenile cataract. Preoperative assessments included biometry (IOLMaster 500/700, Carl Zeiss Meditec, Germany). To evaluate the measurements, we compared the mean prediction error (MPE), mean and median absolute prediction error (MAE, MedAE) of six different formulas, and number of eyes within ± 0.5, ± 1.0, ± 2.0D of target refraction. Postoperative spherical equivalent was measured by retinoscopy 4-12 weeks after surgery.
RESULTS
66 eyes matched our inclusion criteria with a mean age of 6.3 years ± 3.2. MedAE was lowest in SRK/T (0.55D ± 1.08) followed by Holladay I (0.75D ± 1.00), EVO 2.0 (0.80D ± 0.89), Barrett Universal II (BUII, 0.86D ± 1.00), Hoffer Q (0.97 D ± 0.94), and Haigis (1.10D ± 0.95). Regarding eyes within ± 0.5D SRK/T (45.5.%, 30 eyes) performed best, followed by Holladay I (36.4%, 24 eyes), EVO 2.0 and BUII (each 34.8%, 23 eyes). There was a myopic shift seen in all formulas (MPE: -0.21 to -0.90D).
CONCLUSION
Using modern formulas, or even AI formulas, for IOL calculation in children's eyes does barely improve predictability of the postoperative refraction. A myopic shift can be found for all formulas. However, specific formulas like SRK/T seem to better anticipate this.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.