MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acsami.5c09215

Медицинская библиотека · ACS applied materials & interfaces · 2025

Real-Time Impedimetric Monitoring of 3D Cancer Spheroids Using a PDA-Functionalized Microelectrode Platform Integrated with Graphene Quantum Dot-Based Nanocomposites.

Pham Duc-Trung, Park JaeHwan, Vu Phu Chi, Tieu My-Van, Park Sungho, Le Hien Ngoc Thi, Hoang Thi Xoan, Kim Jae Young, Cho Sungbo

СтатьяПеревод в очереди

Аннотация

We describe a bioelectronic interface that combines indium tin oxide (ITO) microelectrode integrated with polydimethylsiloxane (PDMS) microwells to allow real-time monitoring of tumor responses in three dimensions (3D). This design combines PDMS microwells with an ITO microelectrode array that has been improved by polydopamine (PDA) polymerization to make it more biocompatible. The present study employed a unique nanocomposite, Cryptotanshinone (CPT) conjugated to graphene quantum dots (GQDs), exhibiting remarkable anticancer characteristics. The stability and targeted distribution of CPT were significantly enhanced by GQDs, hence amplifying its antiproliferative actions. Real-time resistance measurements revealed substantial differences in the half-maximal inhibitory concentrations (IC50) of the two-dimensional (2D) and 3D cancer models, with values of 0.62 ± 0.14 and 1.47 ± 0.16 μg/mL, respectively. Comprehensive materials characterization and biological validation through gene expression and flow cytometry confirmed the platform's reliability. This materials-centric approach establishes a robust interface between biological systems and electronic monitoring, offering possibilities for drug screening applications.

Для цитирования: Pham Duc-Trung, Park JaeHwan, Vu Phu Chi, Tieu My-Van, Park Sungho, Le Hien Ngoc Thi, Hoang Thi Xoan, Kim Jae Young, Cho Sungbo. Real-Time Impedimetric Monitoring of 3D Cancer Spheroids Using a PDA-Functionalized Microelectrode Platform Integrated with Graphene Quantum Dot-Based Nanocomposites.. ACS applied materials & interfaces. 2025. DOI: 10.1021/acsami.5c09215.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.