Infections of cardiac implantable electronic devices: a retrospective multicenter observational study.

Viola George M, Awan Leah L, Ostrosky-Zeichner Luis, Chan Wenyaw, Darouiche Rabih O

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод в очереди

Аннотация

Infections of cardiac implantable electronic devices (CIED) can cause significant morbidity, mortality, and financial burden. Although staphylococcal organisms account for most infections of these cardiac devices, approximately 20% of all CIED-related infections are caused by non-Staphylococcus species. Herein we describe and compare the demographics, clinical presentation, and outcomes of Staphylococcus aureus and non-staphylococcal infections of CIED.We performed a retrospective, multicenter, observational study of patients from 4 academic hospitals in Houston between 2002 and 2009. All 80 identified non-staphylococcal CIED-related infections were matched, at a 1:1 ratio, to S. aureus infections.Although the demographics and general comorbidities in the 2 study groups were relatively similar, the S. aureus group had a higher proportion of patients with coronary artery disease, diabetes mellitus, and end-stage renal disease. Additionally, 81% of S. aureus compared with only 48.5% of the non-staphylococcal CIED-related infections were health care-associated (p < 0.001). Furthermore, when compared to non-staphylococcal infections, the S. aureus group had more indwelling intravascular foreign material (p < 0.001), more rapid clinical progression (p < 0.001), and overall worse clinical presentation (p < 0.001). However, after stratifying by clinical presentation, the mortality rates in the 2 groups were similar (p = 0.45).Since approximately one-fifth of all CIED-related infections are caused by non-staphylococcal organisms, and untimely antibiotic treatment can result in serious complications, it may be prudent to broaden empiric antimicrobial therapy to cover both Gram-positive and -negative bacteria, until the causative organism is identified.

Для цитирования: Viola George M, Awan Leah L, Ostrosky-Zeichner Luis, Chan Wenyaw, Darouiche Rabih O. Infections of cardiac implantable electronic devices: a retrospective multicenter observational study.. Medicine. 2012. DOI: 10.1097/md.0b013e31825592a7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.