MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bjo-2022-322535

Медицинская библиотека · The British journal of ophthalmology · 2024

Quantitative analysis of choriocapillaris flow deficits and choroidal thickness in children with Marfan syndrome.

Ng Kityee, Xu Pusheng, Jin Guangming, Cheng Weijing, Luo Xiaoling, Ding Xiaoyan, Zheng Danying, Liu Yizhi

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To evaluate the characteristics and associated factors of choroidal thickness (ChT) and choriocapillaris flow deficit percentage (CC FD%) in children with Marfan syndrome (MFS).

METHODS

This is a cross-sectional study. The ChT of the subfoveal area and other areas 0.5, 1.5, and 2.5 mm away from the fovea were assessed. The CC FD% of quadrant and circular regions with diameters of 0.5, 1.5 and 2.5 mm were assessed with 3×3 mm macular choriocapillaris images. Best-corrected visual acuity (BCVA) and cardiac function factor such as Z score were measured to analyse the associations with ChT and CC FD%.

RESULTS

51 MFS children and 50 healthy controls were enrolled in this study. Compared with the healthy controls, the ChT in the MFS group was thinner in the subfoveal area, temporal 0.5, 1.5 and 2.5 mm (all p<0.001). The CC FD% was higher in circle 0.5, 1.5 and 2.5 mm (all p<0.001). Multivariate regression analysis showed that CC FD% in the circle 2.5 mm when the Z score ≥2 was associated with BCVA (β=9.08 (95% CI 3.96 to 14.20); p=0.005) and Z score (β=4.19 (95% CI 1.28 to 12.00); p=0.012).

CONCLUSIONS

Thinner ChT and a higher CC FD% were observed in children with MFS, and an increased CC FD% in circle 2.5 mm was significantly associated with worse BCVA and cardiac function. These findings may help identify future visual impairment and early cardiac events in MFS children.

Для цитирования: Ng Kityee, Xu Pusheng, Jin Guangming, Cheng Weijing, Luo Xiaoling, Ding Xiaoyan, Zheng Danying, Liu Yizhi. Quantitative analysis of choriocapillaris flow deficits and choroidal thickness in children with Marfan syndrome.. The British journal of ophthalmology. 2024. DOI: 10.1136/bjo-2022-322535.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.