MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ultrasmedbio.2026.05.010

Медицинская библиотека · Ultrasound in medicine & biology · 2026

A Coarse-to-Fine DoubleUNet Framework with Synergistic Loss for Accurate Fetal Head Circumference Measurement.

Liu Xixi, Hu Xiaoyang, Liu Hao

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Fetal head circumference (HC) measurement is a routine and indispensable examination during pregnancy, closely associated with fetal health and maternal delivery planning. To reduce the manual workload of sonographers, deep learning has been increasingly applied to this task, with promising outcomes. In this study, we propose a coarse-to-fine deep learning framework for the automatic segmentation and measurement of fetal HC from ultrasound images.

METHODS

We propose SDUNet, a DoubleUNet-based framework enhanced with a tailored synergistic loss for fetal HC segmentation. The synergistic loss integrates multiple complementary loss terms and dynamically balances their contributions during training. This adaptive mechanism encourages physiologically plausible head shapes while reducing errors caused by speckle noise and boundary ambiguity in ultrasound images. SDUNet was trained on the publicly available HC18 data set and further validated on an independent external data set, without applying any post-processing.

RESULTS

The proposed method achieved superior segmentation and measurement performance. Specifically, it obtained a Dice coefficient of 98.60%, Jaccard index of 97.24%, Hausdorff distance of 0.70 mm, average symmetric surface distance of 0.17 mm, boundary F1-score of 99.45%, mean absolute error of 1.12 mm and percentage mean absolute error of 0.75%. The method further demonstrated strong generalization on the external data set.

CONCLUSIONS

Experimental results demonstrate that the SDUNet framework can effectively segment fetal head regions and provide highly accurate HC measurements.

Для цитирования: Liu Xixi, Hu Xiaoyang, Liu Hao. A Coarse-to-Fine DoubleUNet Framework with Synergistic Loss for Accurate Fetal Head Circumference Measurement.. Ultrasound in medicine & biology. 2026. DOI: 10.1016/j.ultrasmedbio.2026.05.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.