Thrombosis and haemostasis · 2017
Microfluidic coagulation assay for monitoring anticoagulant therapy in acute stroke patients.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Bluecher Annemarie, Meyer Dos Santos Sascha, Ferreirós Nerea, Labocha Sandra, Meyer Dos Santos Isabel Maria Rodrigues, Picard-Willems Bettina, Harder Sebastian, Singer Oliver C
Аннотация
Reliable detection of anticoagulation status in patients treated with non-vitamin K antagonist oral anticoagulants (NOACs) is challenging but of importance especially in the emergency setting. This study evaluated the potential of a whole-blood clotting time assay based on Surface Acoustic Waves (SAW-CT) in stroke-patients. The SAW-technology was used for quick and homogenous recalcification of whole blood inducing a surface-activated clotting reaction quantified and visualised by real-time fluorescence microscopy with automatic imaging processing. In 20 stroke or transient ischaemic attack (TIA)-patients taking NOACs kinetics of SAW-CT were assessed and correlated to other coagulation parameters (PT, aPTT) and NOAC-plasma concentration measured by tandem mass spectrometry (LC-MS/MS). In 225 emergency patients with suspicion of acute stroke or TIA, SAW-CT values were assessed. Mean (± SD) SAW-CT in non-anticoagulated stroke patients (n=180) was 124 s (± 21). In patients on dabigatran or rivaroxaban, SAW-CT values were significantly higher 2 and 8 hours (h) after intake rising up to 267 seconds (s) (dabigatran, 2 h after intake) and 250 s (rivaroxaban, 8 h after intake). In patients on apixaban, SAW-CT values were only moderately increased 2 h after intake (SAW-CT 153 s). In emergency patients, SAW-CT values were significantly higher in NOAC and vitamin K antagonist (VKA)-treated as compared to non-anticoagulated patients. In conclusion, the SAW-CT assay is capable to monitor anticoagulant level and effect in patients receiving dabigatran, rivaroxaban and the VKA phenprocoumon. It has a limited sensitivity for apixaban-detection. If specific SAW-CT results were used as cut-offs, SAW-CT yields high diagnostic accuracy to exclude relevant rivaroxaban and dabigatran concentrations in stroke-patients.
Предметные рубрики MeSH
Administration, OralAgedAged, 80 and overAnticoagulantsAutomation, LaboratoryBlood CoagulationChromatography, High Pressure LiquidDabigatranDrug MonitoringFemaleHumansIschemic Attack, TransientMaleMicrofluidic Analytical TechniquesMicroscopy, FluorescenceMiddle AgedPhenprocoumonPredictive Value of TestsPyrazolesPyridonesReproducibility of ResultsRivaroxabanStrokeTandem Mass SpectrometryTime FactorsTreatment OutcomeWhole Blood Coagulation Time