MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1515/cclm.2011.005

Медицинская библиотека · Clinical chemistry and laboratory medicine · 2010

Determination of daptomycin in human plasma by liquid chromatography-tandem mass spectrometry. Clinical application.

Verdier Marie-Clémence, Bentué-Ferrer Danièle, Tribut Olivier, Collet Nicolas, Revest Matthieu, Bellissant Eric

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Daptomycin is a recently developed cyclic lipopeptide antibiotic active against most Gram-positive pathogens including vancomycin-resistant enterococci and methicillin-resistant Staphylococcus aureus. To optimize treatment efficacy and safety, especially in patients undergoing multiple drug regimens and/or co-morbidities, a specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the quantification of daptomycin in plasma.

METHODS

A C18 column was used for separation, with a mobile phase initially consisting of 0.1% formic acid, water, and acetonitrile (ACN) in a linear gradient from 20% to 70%. After protein precipitation with ACN, the clear upper layer was diluted in water:ACN (50:50, v/v) before injection. Detection was performed using an electrospray ionization technique. MS/MS transitions, monitored in the positive ion mode were m/z 811.1 → m/z 313.1 for daptomycin, and m/z 609.4 → m/z 194.9 for reserpine, used as internal standard.

RESULTS

Elution of daptomycin and reserpine occurred at 4.5 and 3.9 min, respectively. The method was validated over a range of concentrations from 1 mg/L to 120 mg/L. The assay met recommended acceptance criteria: coefficients of variation were <6.3% and <7.4%, and accuracies were between -5.9% and +11.2% and between -3.5% and +3.7%, for intra- and inter-day validations, respectively.

CONCLUSIONS

This method appears well-adapted to routine hospital practice for therapeutic drug monitoring of daptomycin considering its time of analysis, range of concentrations measured, precision and accuracy.

Для цитирования: Verdier Marie-Clémence, Bentué-Ferrer Danièle, Tribut Olivier, Collet Nicolas, Revest Matthieu, Bellissant Eric. Determination of daptomycin in human plasma by liquid chromatography-tandem mass spectrometry. Clinical application.. Clinical chemistry and laboratory medicine. 2010. DOI: 10.1515/cclm.2011.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.