MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/pmrj.12809

Медицинская библиотека · PM & R : the journal of injury, function, and rehabilitation · 2022

The effect of axillary crutch length on upper limb kinematics during swing-through gait.

Kuntze Gregor, Russell Monica, Jivan Shaine, Ronsky Janet Lenore, Manocha Ranita Harpreet Kaur

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Axillary crutches are commonly used in rehabilitation. Inappropriately fit crutches may result in upper limb pain or injury.

OBJECTIVE

To investigate the effects of axillary crutch length on upper limb kinematics to better understand potential injury mechanisms. It was hypothesized that crutches that were longer or shorter than standard-fit crutches would alter upper limb kinematics.

DESIGN

Cross-sectional.

SETTING

Gait laboratory.

PARTICIPANTS

Fifteen healthy males with no prior crutch experience.

INTERVENTIONS: Participants were fit with axillary crutches using standardized methods, as well as with crutches that were 5 cm longer and 5 cm shorter. Participants performed swing-through gait (1.20 ± 0.07 ms-1 ) with all crutch lengths in randomized order. Kinematics were recorded using an optical motion-tracking system and joint angles for the scapula, shoulder, elbow, and wrist were computed.

MAIN OUTCOME MEASURES: The effects of crutch length on joint range of motion (ROM) and joint angles at initial crutch contact were analyzed using multivariate analysis (Hotelling's T2 ; α = .025) and simultaneous confidence intervals (CI).

RESULTS

The long-standard crutch fit comparison showed effects across all joints (ROM p = .009; initial contact p < .001). Longer crutches resulted in greater scapular upward rotation (mean difference [95% CI] ROM: 1.0 [-0.2 to 2.2]; initial contact: -2.7 [-4.4, -1.1]) and shoulder abduction (ROM: 0.8 [-0.1 to 1.8]; initial contact: -1.9 [-4.1 to 0.3]). Crutch length also had effects across all joints for the short-standard fit comparison (ROM p = .004; initial contact p = .016). Shorter crutches resulted in greater scapula downward rotation (2.2 [-0.4 to 4.8]) and greater shoulder adduction (2.5 [-0.6 to 5.6]) at initial contact. Shorter crutches also reduced shoulder flexion/extension ROM (-2.5 [-4.4 to -0.6]).

CONCLUSIONS

Altered crutch length results in scapular and shoulder kinematic deviations that may present risk factors for upper limb injury with crutch-walking. This may underline the importance of appropriate device fitting to reduce injury risk in crutch users.

Для цитирования: Kuntze Gregor, Russell Monica, Jivan Shaine, Ronsky Janet Lenore, Manocha Ranita Harpreet Kaur. The effect of axillary crutch length on upper limb kinematics during swing-through gait.. PM & R : the journal of injury, function, and rehabilitation. 2022. DOI: 10.1002/pmrj.12809.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.