European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2025
Evaluation of multiple ventricular septal defects using three-dimensional reconstruction models†.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yoshimura Naoki, Aoki Masaya, Toritsuka Daisuke, Motono So, Nagura Saori, Doi Toshio, Fukahara Kazuaki, Nakaoka Hideyuki, Ibuki Keijiro, Ozawa Sayaka, Hirono Keiichi
Аннотация
OBJECTIVES: Although there has been rapid development in the field of three-dimensional morphological analyses of congenital heart disease, with the three-dimensional volume-rendered images providing visualization of the external vascular anatomy, the precise reproduction of 'Swiss-cheese' ventricular septum is not well established. We created three-dimensional printed models and computer graphics based on multi-slice computed tomography of patients with complex multiple ventricular septal defects for surgical decision planning of this difficult cardiac defect.
METHODS: Seven patients with complex multiple ventricular septal defects were evaluated preoperatively using 3-dimensional printed models and computer graphics to plan therapeutic interventions.
RESULTS: The three-dimensional printed models detected muscular VSDs in 9 out of 15 (60%) regions. On the other hand, 3-dimensional computer graphics detected 10 out of 15 (67%) regions. The 3-dimensional printed models and computer graphics allowed the evaluation of the muscular ventricular septal defects from both the left and right ventricular aspects of the septum.
CONCLUSIONS: Our preliminary experiences suggest that three-dimensional printed models and computer graphics can help plan surgery in patients with complex multiple ventricular septal defects. Three-dimensional printed models allowed surgeons to understand the three-dimensional positioning of complex multiple ventricular septal defects preoperatively. High-quality three-dimensional computer graphics provided precise information about the size, shape and localization of muscular ventricular septal defects especially from the left ventricular side.
METHODS: Seven patients with complex multiple ventricular septal defects were evaluated preoperatively using 3-dimensional printed models and computer graphics to plan therapeutic interventions.
RESULTS: The three-dimensional printed models detected muscular VSDs in 9 out of 15 (60%) regions. On the other hand, 3-dimensional computer graphics detected 10 out of 15 (67%) regions. The 3-dimensional printed models and computer graphics allowed the evaluation of the muscular ventricular septal defects from both the left and right ventricular aspects of the septum.
CONCLUSIONS: Our preliminary experiences suggest that three-dimensional printed models and computer graphics can help plan surgery in patients with complex multiple ventricular septal defects. Three-dimensional printed models allowed surgeons to understand the three-dimensional positioning of complex multiple ventricular septal defects preoperatively. High-quality three-dimensional computer graphics provided precise information about the size, shape and localization of muscular ventricular septal defects especially from the left ventricular side.