MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/01.cir.0000118474.71662.e3

Медицинская библиотека · Circulation · 2004

Randomized study to evaluate sirolimus-eluting stents implanted at coronary bifurcation lesions.

Colombo Antonio, Moses Jeffrey W, Morice Marie Claude, Ludwig Josef, Holmes David R, Spanos Vassilis, Louvard Yves, Desmedt Benny, Di Mario Carlo, Leon Martin B

Клиническое исследованиеСравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

A sirolimus-eluting stent (Cypher, Cordis Corp) has been reported to markedly decrease restenosis in selected lesions; higher-risk lesions, including coronary bifurcations, have not been studied.

METHODS AND

RESULTS

This prospective study evaluated the safety and efficacy of sirolimus-eluting stents for treatment of coronary bifurcation lesions. Patients were randomly assigned to either stenting of both branches (group A) or stenting of the main branch with provisional stenting of the side branch (SB) (group B). Eighty-five patients (86 lesions) were enrolled. There was 1 case of unsuccessful delivery of any device at the bifurcation site. Given the high crossover, more lesions were treated with 2 stents (n=63) than with stent/balloon (n=22). Clinical follow-up at 6 months was completed in all patients and angiographic follow-up in 53 patients in group A (85.5%) and 21 in group B (95.4%). One patient died suddenly 4.5 months after the procedure. There were 3 cases of stent thrombosis (3.5%). The total restenosis rate at 6 months was 25.7%, and it was not significantly different between the double-stenting (28.0%) and the provisional SB-stenting (18.7%) groups. Fourteen of the restenosis cases occurred at the ostium of the SB and were focal. Target lesion revascularization was performed in 7 cases; target vessel failure occurred in 15 cases (17.6%).

CONCLUSIONS

These results are an improvement compared with historical controls using bare metal stents. Restenosis at the SB remains a problem. At this time, no statement can be made regarding the most appropriate technique to use when treating bifurcations with the Cypher stent.

Для цитирования: Colombo Antonio, Moses Jeffrey W, Morice Marie Claude, Ludwig Josef, Holmes David R, Spanos Vassilis, Louvard Yves, Desmedt Benny, Di Mario Carlo, Leon Martin B. Randomized study to evaluate sirolimus-eluting stents implanted at coronary bifurcation lesions.. Circulation. 2004. DOI: 10.1161/01.cir.0000118474.71662.e3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.