MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/mus.27217

Медицинская библиотека · Muscle & nerve · 2021

Laboratory monitoring of nusinersen safety.

Goedeker Natalie L, Gibbons Jennifer L, Varadhachary Arun S, Connolly Anne M, Zaidman Craig M

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

This retrospective study reports our tertiary care center's experience with intrathecal nusinersen administration in children and adults with spinal muscular atrophy (SMA).

METHODS

We reviewed safety monitoring laboratory results and need for procedural sedation and fluoroscopy-guidance in all SMA patients receiving nusinersen between February 2017 and March 2020.

RESULTS

Fifty-eight patients ages 1 mo- 56 y received 494 nusinersen doses. There were 166 laboratory abnormalities in 45 patients. Most were either mild (145 [87.3%]) or were transient proteinuria (18 [10.8%]). None altered nusinersen treatment. Twenty-eight patients required either general anesthesia (75 doses) or anxiolysis with oral midazolam (133 doses, including 6 patients [23 doses] with SMA type I). Eight patients with complicated spines (45 doses) required fluoroscopic guidance. One treatment-related serious adverse event (emesis leading to intubation) occurred during general anesthesia. Two children had asymptomatic increased intracranial pressure. No patients discontinued treatment due to adverse events.

DISCUSSION: Intrathecal nusinersen is generally safe and well-tolerated, including in patients requiring oral anxiolysis, general sedation, and fluoroscopic guidance. Frequent serial laboratory monitoring did not identify any persistent significantly abnormal findings or alter treatment.

Для цитирования: Goedeker Natalie L, Gibbons Jennifer L, Varadhachary Arun S, Connolly Anne M, Zaidman Craig M. Laboratory monitoring of nusinersen safety.. Muscle & nerve. 2021. DOI: 10.1002/mus.27217.