OBJECTIVES

To estimate the safety, tolerability, and acceptability of loop electrosurgical excision procedure (LEEP) for cervical intraepithelial neoplasia (CIN 2 or 3) in human immunodeficiency virus (HIV)-positive women performed by nonphysician health care providers in an HIV care and treatment clinic.

METHODS

We performed a prospective cohort study among women undergoing LEEP for biopsy-confirmed CIN 2 or 3 at the Family Acquired Immunodeficiency Syndrome Care and Education Services Clinic in Kisumu, Kenya. Women were followed-up 4 weeks after the procedure and questioned for abstinence as well as presence and severity of side effects after the procedure. The results were analyzed using descriptive statistics and univariable and multivariable analysis.

RESULTS

Among the 180 (91%) women who returned for a 4-week follow up after LEEP, 52% reported at least one postprocedure symptom, including bleeding, discharge, or pain. Using a Likert scale for severity of symptoms, 179 (99%) reported very mild to mild symptoms, whereas one (1%) participant described the symptoms as moderate. No participants reported severe symptoms. Mean CD4 count was significantly higher among women who reported any symptoms compared with women who reported no symptoms after LEEP (419 cells/mm compared with 349 cells/mm, P<.05), an association that remained significant after adjustment for antiretroviral treatment. The presence or severity of postprocedure symptoms did not differ among women who reported sexual activity (16%) less than 4 weeks after the procedure.

CONCLUSION

LEEP performed by clinical officers was well-accepted by HIV-positive women and appears safe, resulting in minimal side effects, even among women with early resumption of intercourse.

LEVEL OF EVIDENCE: II.

Для цитирования: Woo Victoria G, Cohen Craig R, Bukusi Elizabeth A, Huchko Megan J. Loop electrosurgical excision procedure: safety and tolerability among human immunodeficiency virus-positive Kenyan women.. Obstetrics and gynecology. 2011. DOI: 10.1097/aog.0b013e31822b0991.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.