MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jpedsurg.2017.04.011

Медицинская библиотека · Journal of pediatric surgery · 2017

Does an external chest wall measurement correlate with a CT-based measurement in patients with chest wall deformities?

Ewert Franziska, Syed Julia, Wagner Sonja, Besendoerfer Manuel, Carbon Roman T, Schulz-Drost Stefan

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Measurements in chest wall deformities are typically conducted using a thorax caliper or a CT scan of the chest wall. This paper focuses on the possible correlation between these two methods to validate the reliability of the thorax caliper, minimize radiation exposure, and limit the usage of expensive imaging techniques.

METHODS

We evaluated 95 consecutive patients (77 pectus excavatum (PE), 17 pectus carinatum (PC), 1 mixed deformity) who received surgical correction of the anterior chest wall. The results of the external chest wall measurements and the CT-based measurements were statistically compared.

RESULTS

A significant correlation between the two measurements was observed in PE and PC at the highest point of the deformation. The strongest correlation was noted in PE. We also noted a correlation between the transverse diameter of the external measurement and the inner thoracic diameter of the CT scan but not for the sagittal diameters in the upper parts of the sternum.

CONCLUSIONS

Thorax caliper measurements are suitable for determining the sagittal thoracic diameter at the maximum level of the deformity and the transverse diameter with an accuracy comparable to that of CT measurements. Since these values key, the thorax caliper is reliable for monitoring and documenting chest wall malformations.

LEVEL OF EVIDENCE: Study of diagnostic test. Testing previously developed diagnostic criteria in a consecutive series of patients and a universally "gold" standard-Level I.

Для цитирования: Ewert Franziska, Syed Julia, Wagner Sonja, Besendoerfer Manuel, Carbon Roman T, Schulz-Drost Stefan. Does an external chest wall measurement correlate with a CT-based measurement in patients with chest wall deformities?. Journal of pediatric surgery. 2017. DOI: 10.1016/j.jpedsurg.2017.04.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.