MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.scitotenv.2022.158469

Медицинская библиотека · The Science of the total environment · 2022

A quantitative study of the effects of particle' properties and environmental conditions on the electron efficiency of Pd and sulfidated nanoscale zero-valent irons.

Gong Li, Zhang Zaizhi, Xia Chenyun, Zheng Jing, Gu Yawei, He Feng

СтатьяПеревод в очереди

Аннотация

Electron efficiency (or electron selectivity, ɛe) is an important quantitative criterion for zero-valent iron treatment of organohalide contaminated groundwater. The aim of this quantitative study was the systematic exploration and comparison of the effects of the Pd/Fe and S/Fe molar ratios (i.e., [Pd/Fe] and [S/Fe]), trichloroethylene (TCE) concentrations ([TCE]), pH solution, aging time, and water matrices on the ɛe of Pd-nZVI and S-nZVI. To this end, we used TCE as a probe contaminant. The ɛe of Pd-nZVI increased and then decreased with [Pd/Fe], while that of S-nZVI increased with [S/Fe], as more hydrophobic FeS2 was formed on S-nZVI at higher [S/Fe]. The εe of S-nZVI and Pd-nZVI increased with increasing [TCE]. Specifically, the εe of S-nZVI and Pd-nZVI at [TCE] of 200 ppm increased by 24.9 % and 79.3 %, respectively, compared with that at [TCE] of 10 ppm. As the H2 evolution reaction (HER) was more sensitive to surface passivation than TCE dechlorination, the εe of S-nZVI and Pd-nZVI under alkaline conditions was higher than that under basic conditions, and increased by 11.7 % and 37.8 %, respectively, at pH 10 relative to that at pH 6. The εe also increased with the aging time of the S-nZVI and Pd-nZVI particles; the increase was by 27.2 % and 59.6 %, respectively, at aging time of 30 d compared with that of the fresh ones. The ɛe of both particles were higher in artificial groundwater (AGW) than in real groundwater (RGW). For all batch experiments, the εe of S-nZVI increased over the reaction time and tended to outperform that of Pd-nZVI, even though the εe of Pd-nZVI was higher than that of S-nZVI at the initial stage of TCE dechlorination, thereby justifying the longevity of S-nZVI.

Для цитирования: Gong Li, Zhang Zaizhi, Xia Chenyun, Zheng Jing, Gu Yawei, He Feng. A quantitative study of the effects of particle' properties and environmental conditions on the electron efficiency of Pd and sulfidated nanoscale zero-valent irons.. The Science of the total environment. 2022. DOI: 10.1016/j.scitotenv.2022.158469.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.