MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajogmf.2022.100778

Медицинская библиотека · American journal of obstetrics & gynecology MFM · 2022

Comparative retrospective study on the validity of point-of-care testing device for massive obstetrical hemorrhage: dry hematology vs thromboelastography.

Nakamura Eishin, Matsunaga Shigetaka, Kikuchi Akihiko, Takai Yasushi

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Early recognition of hypofibrinogenemia and prompt initiation of transfusion therapy in patients with massive obstetrical hemorrhage can improve prognosis. There are reports on the usefulness of point-of-care testing, which provides quicker test results compared with fibrinogen measurements using the conventional Clauss method.

OBJECTIVE

This study aimed to compare and investigate the diagnostic accuracy of dry hematology and thromboelastography in point-of-care testing for the diagnosis of hypofibrinogenemia.

STUDY

DESIGN

A single-center, retrospective study of 126 massive obstetrical hemorrhage cases with point-of-care testing before treatment was initiated. The correlation of fibrinogen values with the Clauss method and the diagnostic accuracy for hypofibrinogenemia were compared between dry hematology and thromboelastography.

RESULTS

Fibrinogen value in dry hematology showed a strong positive correlation with values measured by the Clauss method, and the diagnostic accuracy for hypofibrinogenemia was high, but there were many residuals above 100 mg/dL, and the distribution of these residuals was not uniform. Although thromboelastography cannot be used to directly measure fibrinogen values, maximum amplitude citrated functional fibrinogen, amplitude-10 citrated rapid thromboelastography, and amplitude-10 citrated functional fibrinogen showed a strong positive correlation with fibrinogen values using the Clauss method, and no significant difference in correlation or diagnostic accuracy was observed relative to dry hematology.

CONCLUSION

Dry hematology and thromboelastography were equally accurate in diagnosing hypofibrinogenemia, with results correlating well with fibrinogen values measured by the Clauss method.

Для цитирования: Nakamura Eishin, Matsunaga Shigetaka, Kikuchi Akihiko, Takai Yasushi. Comparative retrospective study on the validity of point-of-care testing device for massive obstetrical hemorrhage: dry hematology vs thromboelastography.. American journal of obstetrics & gynecology MFM. 2022. DOI: 10.1016/j.ajogmf.2022.100778.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.