MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/bot.0b013e3181aa5402

Медицинская библиотека · Journal of orthopaedic trauma · 2009

Precontoured parallel plate fixation of AO/OTA type C distal humerus fractures.

Athwal George S, Hoxie Samuel C, Rispoli Damian M, Steinmann Scott P

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To determine the clinical effectiveness of precontoured parallel plating for the management of Orthopaedic Trauma Association (OTA) type C distal humerus fractures.

DESIGN

Retrospective case series.

SETTING

Level I trauma center.

PATIENTS/

PARTICIPANTS

Between 2001 and 2005, 37 patients with OTA type C distal humerus fractures underwent open reduction and internal fixation exclusively with the Mayo Elbow Congruent Plating system. Thirty-two patients consented to participate in the study.

INTERVENTION: All patients underwent open reduction and internal fixation with a precontoured bicolumn parallel plating system.

MAIN OUTCOME MEASUREMENTS: Range of motion, Mayo Elbow Performance Score, Disabilities of the Arm, Shoulder and Hand score (DASH), complication rate, and radiographic evaluation.

RESULTS

At a mean of 27 months follow up, the mean arc of elbow flexion-extension motion was 97 degrees (range, 10 degrees -145 degrees ). The mean Mayo Elbow Performance Score was 82 points and the mean DASH score was 24 points. There were no implant failures and all distal humerus fractures healed. A total of 24 complications occurred in 17 patients (53%) with five patients (16%) having postoperative nerve injuries.

CONCLUSIONS

Open reduction and internal fixation with a precontoured parallel plating system is an effective treatment method for OTA type C distal humerus fractures. Despite this, the fact that over half of the patients had a significant complication will require utmost vigilance on the part of the surgeon to avoid intraoperative complications. Patient counseling is paramount.

Для цитирования: Athwal George S, Hoxie Samuel C, Rispoli Damian M, Steinmann Scott P. Precontoured parallel plate fixation of AO/OTA type C distal humerus fractures.. Journal of orthopaedic trauma. 2009. DOI: 10.1097/bot.0b013e3181aa5402.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.