INTRODUCTION

Infantile nystagmus and foveal hypoplasia associated with AHR gene defects is a newly recognized and rare disorder. Our aim was to present a patient with a novel biallelic AHR pathogenic variant with electrophysiological evidence of chiasmal misrouting.

MATERIALS AND

METHODS

Complete ocular examination, fundus imaging, visual evoked potentials (VEP) and full-field electroretinography were performed at initial presentation. Genetic testing was performed by whole exome sequencing.

RESULTS

Female patient of 6 years old presented a reduced best corrected visual acuity, an infantile nystagmus and a grade III typical foveal hypoplasia without ocular hypopigmentation. A crossed asymmetry was discovered on pattern onset/offset VEP. Genetic testing put in evidence a novel homozygous variant in AHR: c.2242del, p. (Gln748Lysfs*5). During 11-years follow-up period, BCVA gradually improved. There was no evidence of retinal degeneration.

CONCLUSION

AHR gene defects could be associated with infantile nystagmus, foveal hypoplasia and chiasmal misrouting.

Для цитирования: Smirnov Vasily M, Lasseaux Eulalie, Michaud Vincent, Courdier Cécile, Meunier Isabelle, Arveiler Benoit, Defoort-Dhellemmes Sabine. Crossed VEP asymmetry in a patient with AHR-linked infantile nystagmus and foveal hypoplasia.. Documenta ophthalmologica. Advances in ophthalmology. 2024. DOI: 10.1007/s10633-024-09979-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.