DOI 10.1007/s10140-025-02435-1

Медицинская библиотека · Emergency radiology · 2026

Computed tomography scan evaluation of Globe rupture using a novel mnemonic : a single center experience.

Khasawneh Ruba, Hajij Ammar, Abdo Nour, Alzu'bi Yazan O, Al-Shalabi Bashar, Al Sharie Ahmed H, Khasawneh Firas A, Mohaidat Mohammad Z

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Globe rupture presents a diagnostic challenge because of potentially vision-threatening outcomes. Although computed tomography (CT) is critical for assessment, a structured interpretation approach is often lacking. This study introduces the novel "FLAP CONE" mnemonic to assist radiologists in evaluating globe rupture.

METHODS

This was a retrospective study of 143 patients (151 eyes) with suspected globe rupture between January 2015 and December 2020. The male-to-female ratio was 3:1, with a median age of 22 years. Demographics and mechanisms of injury were recorded. CT scans were independently reviewed by two radiologists using the FLAP CONE mnemonic, encompassing Fractures/Foreign bodies, scleral Lacerations/Lens abnormalities, Anterior chamber changes, Posterior segment abnormalities, eye Contour distortion, Orbital apex hematoma, Neurovascular bundle abnormalities, and Extraocular muscles (EOM)/Emphysema. Findings were documented as binary variables. The diagnostic accuracy, sensitivity, specificity, and interobserver agreement (κ) were calculated.

RESULTS

Sharp objects (39%) and falls (25%) were the leading causes of penetrating and blunt trauma, respectively. Use of the mnemonic achieved 91.9% diagnostic accuracy, with 88.3% sensitivity and 98.5% specificity. Orbital emphysema (43%) was the most frequent finding. Postseptal foreign body and the "flat tire" sign were associated with the highest diagnostic performance (sensitivity of 100% and 97.2%, respectively; specificity, 100%; and PPV, 100%). Kappa values ranged from 0.15 (orbital apex hematoma) to 1.0 (postseptal foreign body), with an overall κ = 0.85. Four clinically confirmed ruptures were missed because of subtle scleral defects and the presence of intraocular gas.

CONCLUSION

The FLAP CONE mnemonic demonstrates excellent diagnostic accuracy and interobserver reliability, providing a systematic and efficient approach to the CT evaluation of globe rupture.

Для цитирования: Khasawneh Ruba, Hajij Ammar, Abdo Nour, Alzu'bi Yazan O, Al-Shalabi Bashar, Al Sharie Ahmed H, Khasawneh Firas A, Mohaidat Mohammad Z. Computed tomography scan evaluation of Globe rupture using a novel mnemonic : a single center experience.. Emergency radiology. 2026. DOI: 10.1007/s10140-025-02435-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.