Surgical management of non-metallic and non-magnetic metallic intraocular foreign bodies.
Аннотация
BACKGROUND AND
OBJECTIVE
To identify clinical features and evaluate outcomes of vitreoretinal surgery in eyes with retained non-metallic and non-magnetic metallic intraocular foreign bodies (IOFBs).
PATIENTS AND
METHODS
Retrospective chart review. Thirty-two eyes (28 patients) with non-metallic and non-magnetic metallic IOFBs underwent removal of IOFBs with intraocular forceps, either via the pars plana in 30 eyes (93.9%) or a limbal approach in 2 eyes (6.25%). The main outcome measures were postoperative visual acuity, rate of retinal break formation, development of retinal detachment, and type of IOFB.
RESULTS
IOFBs were non-metallic in 22 eyes (68.7%) and non-magnetic metallic in 10 eyes (31.1%). The average follow-up period was 7.5 months. Overall, final visual acuity was 20/40 or better in 10 eyes (31.1%) and 5/200 to 20/50 in 10 eyes (31.1%). A higher incidence of retinal break formation posterior to the sclerotomy was seen with glass IOFBs (P = .02). Retinal detachment was observed preoperatively in 4 eyes (12.5%) and postoperatively in 2 eyes (6.25%).
CONCLUSION
Final visual outcome was independent of size and type of IOFB. Pars plana extractions may be associated with a higher rate of retinal break formation and subsequent retinal detachment, particularly with glass IOFBs.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.