MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2337/dc25-1994

Медицинская библиотека · Diabetes care · 2026

INHALE-1: A Multicenter Randomized Trial of Inhaled Technosphere Insulin in Children With Type 1 Diabetes.

Haller Michael J, Kanapka Lauren, Monzavi Roshanak, Mouse Thomas J, Prakasam Gnanagurudasan, Dewan Asheesh K, DiMeglio Linda A, Laffel Lori M, Willi Steven M, Tansey Michael J, Nelson Bryce A, Kashmiri Himala, Wood Jamie R, Latif Kashif, White Perrin, Kipnes Mark, Rodriguez Henry, Smith Joshua, Sparling David P, Malik Faisal S, Cymbaluk Anna, Bhargava Anuj, Ekhlaspour Laya, Beasley Shannon, Cossen Kristina, Wintergerst Kupper A, Fiallo-Scharer Rosanna, Maahs David M, Bethin Kathleen E, Wood Michael A, Hanley Patrick C, Mulukutla Surya N, Van Name Michelle, Blackman Scott M, Gallagher Mary Pat, Clements Mark A, Sheanon Nicole, Reddy Konda, Reiner Barry J, Gal Robin, Beck Roy W, INHALE-1 Study Group*

СтатьяРандомизированное исследованиеМногоцентровое исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To evaluate inhaled technosphere insulin (TI) in children with diabetes.

RESEARCH DESIGN AND

METHODS

A total of 230 youth 4-17 years old with type 1 (98%) or type 2 (2%) diabetes treated with multiple daily injections of insulin were randomly assigned 1:1 to TI or rapid-acting analog (RAA) insulin plus continuation of long-acting basal insulin and continuous glucose monitoring (CGM) for 26 weeks. The primary outcome was change in HbA1c, tested for noninferiority with margin of 0.4%.

RESULTS

In intent-to-treat analysis, mean HbA1c (% ± SD) was 8.22 ± 0.87 at baseline and 8.41 ± 1.38 at 26 weeks with TI and 8.21 ± 0.96 and 8.21 ± 1.10, respectively, with RAA (adjusted difference = 0.18; 95% CI -0.07, 0.43; noninferiority P = 0.091). CGM-measured time in range 70-180 mg/dL was not significantly different between groups (adjusted difference -2.2%; 95% CI -7.0, 2.7; P = 0.38). Two severe hypoglycemic events occurred in the TI group and one in the RAA group. Change in forced expiration volume in 1 s from baseline to 26 weeks did not differ comparing TI and RAA (P = 0.53). The TI group reported greater treatment satisfaction (P = 0.004) and had less gain in weight and BMI percentile (P = 0.009) than did the RAA group.

CONCLUSIONS

The primary analysis did not meet the prespecified criteria for HbA1c noninferiority. However, TI use was safe over 26 weeks without affecting pulmonary function and was associated with greater treatment satisfaction and less weight gain compared with RAA, supporting TI as a treatment option for some pediatric patients with type 1 diabetes.

Для цитирования: Haller Michael J, Kanapka Lauren, Monzavi Roshanak, Mouse Thomas J, Prakasam Gnanagurudasan, Dewan Asheesh K, DiMeglio Linda A, Laffel Lori M, Willi Steven M, Tansey Michael J, Nelson Bryce A, Kashmiri Himala, Wood Jamie R, Latif Kashif, White Perrin, Kipnes Mark, Rodriguez Henry, Smith Joshua, Sparling David P, Malik Faisal S, Cymbaluk Anna, Bhargava Anuj, Ekhlaspour Laya, Beasley Shannon, Cossen Kristina, Wintergerst Kupper A, Fiallo-Scharer Rosanna, Maahs David M, Bethin Kathleen E, Wood Michael A, Hanley Patrick C, Mulukutla Surya N, Van Name Michelle, Blackman Scott M, Gallagher Mary Pat, Clements Mark A, Sheanon Nicole, Reddy Konda, Reiner Barry J, Gal Robin, Beck Roy W, INHALE-1 Study Group*. INHALE-1: A Multicenter Randomized Trial of Inhaled Technosphere Insulin in Children With Type 1 Diabetes.. Diabetes care. 2026. DOI: 10.2337/dc25-1994.