MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/pbc.31916

Медицинская библиотека · Pediatric blood & cancer · 2025

High Prevalence of Abnormal Baseline Lung Function in Pediatric and Young Adult Hematopoietic Stem Cell Transplant Recipients: A Report from the TRANSPIRE Study.

Koo Jane, Cooper Richard, Edwards Stephanie L, Lane Adam, Loveless Sara Katherine, Strecker Lauren, Lake Kelly E, Myers Kasiani C, Towe Christopher, Patti Jessica, Walkup Laura L, Wikenheiser-Brokamp Kathryn A, MacMillan Margaret L, Lacher Philip, Griffin Tamara, Tekman Merve, Cisneros Gabriel Salinas, Wu Kevin, Zinter Matthew S, Urrego Fernando A, Baker K Scott, Abts Matthew F, Ballard Sheri, Freedman Jason L, Caraballo Alexander, Young Lisa R, Josephson Maureen B, Allen Julian L, Camburn Devaney M, Doherty Erin E, Azamian Mashid Sababi, Arredondo Martha, Silva-Carmona Manuel, Lehmann Leslie E, Wong Wai, Gaffin Jonathan M, McAlpine William, Li Mona, Goldfarb Samuel B, Woods Jason C, Davies Stella M

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Pulmonary complications are a major cause of morbidity and mortality in pediatric and young adult hematopoietic stem cell transplant (HSCT) recipients. The impact of preexisting lung dysfunction on posttransplant outcomes remains understudied.

METHODS

In a multi-institutional prospective cohort of 444 patients (≤24 years) undergoing allogeneic HSCT at eight centers, baseline lung function was categorized as normal or abnormal using clinical history, imaging, pulmonary function tests (PFTs), and pulmonologist review. Spirometry and diffusion capacity were assessed at baseline, Day 100, 1 year, and 2 years post-HSCT.

RESULTS

Baseline pulmonary dysfunction was present in 224 patients (50.4%), including impaired spirometry (46.4%), low diffusion capacity (33.8%), and imaging abnormalities (e.g., nodules 19%, interstitial changes 7.9%). These patients had significantly lower median z-scores for forced expiratory volume in 1 s (FEV1) (-2.3 vs. -0.5), forced vital capacity (FVC) (-2.0 vs. -0.3), and diffusion capacity of the lung for carbon monoxide (-2.4 vs. -0.7; all p < 0.001). Lung function impairments persisted through 2 years post-HSCT. FEV1 and FVC remained significantly lower at all time points; FEV1/FVC ratios were similar. Overall survival was lower in the abnormal group (88.4 vs. 95.9%). Seven respiratory-related deaths occurred, including acute respiratory distress syndrome (n = 3), respiratory failure (n = 2), diffuse alveolar hemorrhage (n = 1), and fibrotic lung disease (n = 1).

CONCLUSIONS

Pretransplant pulmonary dysfunction is common and predicts sustained posttransplant impairment and lower survival. Comprehensive baseline assessment may aid in risk stratification and guide early interventions to improve long-term respiratory outcomes in pediatric and young adult HSCT patients.

GOV IDENTIFIER: NCT04098445.

Для цитирования: Koo Jane, Cooper Richard, Edwards Stephanie L, Lane Adam, Loveless Sara Katherine, Strecker Lauren, Lake Kelly E, Myers Kasiani C, Towe Christopher, Patti Jessica, Walkup Laura L, Wikenheiser-Brokamp Kathryn A, MacMillan Margaret L, Lacher Philip, Griffin Tamara, Tekman Merve, Cisneros Gabriel Salinas, Wu Kevin, Zinter Matthew S, Urrego Fernando A, Baker K Scott, Abts Matthew F, Ballard Sheri, Freedman Jason L, Caraballo Alexander, Young Lisa R, Josephson Maureen B, Allen Julian L, Camburn Devaney M, Doherty Erin E, Azamian Mashid Sababi, Arredondo Martha, Silva-Carmona Manuel, Lehmann Leslie E, Wong Wai, Gaffin Jonathan M, McAlpine William, Li Mona, Goldfarb Samuel B, Woods Jason C, Davies Stella M. High Prevalence of Abnormal Baseline Lung Function in Pediatric and Young Adult Hematopoietic Stem Cell Transplant Recipients: A Report from the TRANSPIRE Study.. Pediatric blood & cancer. 2025. DOI: 10.1002/pbc.31916.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.