MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jocmr.2026.102729

Медицинская библиотека · Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2026

Fontan conduit cross-sectional area and relationship to exercise performance.

O'Halloran Conor P, Alsaied Tarek, Wang Alan P, Ward Kendra, Laternser Christina, Files Matthew D, Mines Ellen, Lemley Bethan A, Husain Nazia, Desai Lajja, Rathod Rahul H, Robinson Joshua D, FORCE Investigators

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The synthetic extracardiac (EC) Fontan conduit may become inadequate as patients grow, potentially limiting cardiovascular capacity.

OBJECTIVE

To evaluate the relationship between EC-Fontan conduit cross-sectional area (CSA), indexed to body surface area (BSA), and exercise performance.

METHODS

A cross-sectional analysis of data from the Fontan Outcomes Registry using Clinical Examinations (FORCE) registry was performed. Patients with EC-Fontan anatomy who underwent cardiovascular magnetic resonance imaging (CMR) and cardiopulmonary exercise testing (CPET) within 1 year of each other were analyzed. Median length-averaged and minimum Fontan CSAs were measured using three-dimensional (3D) segmentation and indexed to BSA. The primary outcome was percent predicted peak VO₂ (ppVO₂) on maximal effort CPET. Multivariable linear regression models assessed associations between Fontan CSA/BSA and ppVO₂, adjusting for known predictors of ppVO₂ in Fontan patients.

RESULTS

Of the 493 patients with an EC Fontan and with time-matched CMR and EST, 324 had technically adequate 3D imaging for Fontan conduit measurements and an appropriately documented maximal effort excercise stress test (EST). CMRs occurred at median age of 15 years old and median time of 11 years after Fontan surgery. The median length-averaged and minimum Fontan CSA were 268 mm2 (IQR 227-309mm2) and 229 mm2 (IQR 194-273mm2), respectively. After adjusting for known predictors of ppVO2 in Fontan patients, both minimum and length-averaged Fontan CSA/BSA were positively associated with ppVO2, such that each mm2/m2 increase in minimum CSA/BSA was associated with a 0.08% increase in ppVO2 (p<0.001) or each mm2/m2 increase length-averaged CSA/BSA was associated with a 0.07% increase in ppVO2 (p<0.001). Fontan CSA/BSA was not significantly associated with cardiac function measures at rest, including ejection fraction and cardiac output.

CONCLUSION

Smaller EC-Fontan CSA/BSA is independently associated with reduced exercise capacity after controlling for other known predictors of exercise performance.

Для цитирования: O'Halloran Conor P, Alsaied Tarek, Wang Alan P, Ward Kendra, Laternser Christina, Files Matthew D, Mines Ellen, Lemley Bethan A, Husain Nazia, Desai Lajja, Rathod Rahul H, Robinson Joshua D, FORCE Investigators. Fontan conduit cross-sectional area and relationship to exercise performance.. Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance. 2026. DOI: 10.1016/j.jocmr.2026.102729.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.