Comparison of Doppler Flow Velocity and Thermodilution Derived Indexes of Coronary Physiology.
Аннотация
OBJECTIVES
The aim of this study was to compare Doppler flow velocity and thermodilution-derived indexes and to determine the optimal thermodilution-based diagnostic thresholds for coronary flow reserve (CFR).
BACKGROUND
The majority of clinical data and diagnostic thresholds for flow-based indexes are derived from Doppler measurements, and correspondence with thermodilution-derived indices remain unclear.
METHODS
An international multicenter registry was conducted among patients who had coronary flow measurements using both Doppler and thermodilution techniques in the same vessel and during the same procedure.
RESULTS
Physiological data from 250 vessels (in 149 patients) were included in the study. A modest correlation was found between thermodilution-derived CFR (CFRthermo) and Doppler-derived CFR (CFRDoppler) (r2 = 0.36; P < 0.0001). CFRthermo overestimated CFRDoppler (mean 2.59 ± 1.46 vs 2.05 ± 0.89; P < 0.0001; mean bias 0.59 ± 1.24 by Bland-Altman analysis), the relationship being described by the equation CFRthermo = 1.04 × CFRDoppler + 0.50. The commonly used dichotomous CFRthermo threshold of 2.0 had poor sensitivity at predicting a CFRDoppler value <2.5. The optimal CFRthermo threshold was 2.5 (sensitivity 75.54%, specificity 81.25%). There was only a weak correlation between hyperemic microvascular resistance and index of microvascular resistance (r2 = 0.19; P < 0.0001), due largely to variation in the measurement of flow by each modality. Forty-four percent of patients were discordantly classified as having abnormal microvascular resistance by hyperemic microvascular resistance (≥2.5 mm Hg · cm-1 · s) and index of microvascular resistance (≥25).
CONCLUSIONS
CFR calculated by thermodilution overestimates Doppler-derived CFR, while both parameters show modest correlation. The commonly used CFRthermo threshold of 2.0 has poor sensitivity for identifying vessels with diminished CFR, but using the same binary diagnostic threshold as for Doppler (<2.5) yields reasonable diagnostic accuracy. There was only a weak correlation between microvascular resistance indexes assessed by the 2 modalities.