Low-Dose Computed Tomographic Imaging of Partial Anomalous Pulmonary Venous Connection in Children.
Аннотация
BACKGROUND
In this study, we aimed to determine lobar distribution, drainage sites, and associated cardiovascular anomalies of partial anomalous pulmonary venous connection in pediatric patients using low-dose multidetector computed tomographic angiography.
METHODS
Sixty-one cases (27 female, mean age: 4.7 years) with partial anomalous pulmonary venous connection diagnosed by multidetector computed tomographic angiography were included in this study. In all patients, multidetector computed tomographic angiography examinations were performed using dual-source 256-slice scanner without sedation.
RESULTS
In 61 patients, 73 anomalous pulmonary veins were detected, 56 (77%) of them were right-sided and 17 (23%) were left-sided. Of 56 right-sided anomalous pulmonary veins in 49 patients, 38 (68%) drained into superior vena cava, eight (14%) into atriocaval junction, six (11%) into inferior vena cava, three (5%) into right atrium, and one (2%) into levoatriocardinal vein. Of 17 left-sided anomalous pulmonary veins in 12 patients, 16 (94%) drained into left innominate vein, and one (6%) into coronary sinus. Only seven (12%) patients had isolated partial anomalous pulmonary venous connection, whereas 54 (88%) patients had additional cardiovascular anomalies. The most common (66%) associated anomaly is atrial septal defect. The overall mean effective radiation dose was 1.12 mSv (range: 0.15-7.41 mSv), and it was 0.58 mSv (range: 0.15-0.73) in the patients younger than one-year old.
CONCLUSIONS
The presence and course of the anomalous pulmonary veins and associated cardiovascular anomalies can be reliably detected by dual-source 256-slice multidetector computed tomographic angiography with low radiation doses.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.