MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mnm.0000000000000902

Медицинская библиотека · Nuclear medicine communications · 2018

Comparison of the renal dynamic scan performed with 99mTc-L,L-EC and 99mTc-MAG3 in children with pelviureteric junction obstruction.

Jain Vishesh, Arora Saurabh, Passah Averilicia, Mani Kalaivani, Yadav Devendra K, Goel Prabudh, Gupta Devendra K

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

The aim was to compare the renal dynamic scan (RDS) performed with technetium-99-L,L-ethylene dicysteine (Tc-L,L-EC) and technetium-99-mercaptoacetyltriglycine (Tc-MAG3) in children with pelviureteric junction (PUJ) obstruction. A retrospective study was carried out and children with PUJ obstruction who had RDS performed with both Tc-L,L-EC and Tc-MAG3. Children with any intervention in between the two scans or a gap of more than 2 months in between renal scans were excluded. The dose of each radiotracer used was 0.1 mCi/kg (3.7 MBq/kg), with a minimum dose of 1 mCi (37 MBq). RDS was performed using the F+0 protocol. The differential renal function, Tmax, T1/2, drainage pattern, and hepatic uptake of the radiotracer were recorded and compared. A Bland-Altman plot was used to assess agreement between the two radiotracers. Sixteen children were included in the study. A total of 18 obstructed and 14 normal renal units were available to us for study. The values of differential renal function as well as Tmax and T1/2 of the two radiotracers were in agreement. In three obstructed kidneys in which T1/2 on Tc-MAG3 was greater than 20 min, Tc-L,L-EC showed T1/2 values of 13.3 min or less. Tc-L,L-EC showed nonobstructive drainage in three patients who had shown partial obstruction on Tc-MAG3 scan. The hepatic uptake of Tc-L,L-EC was also lower compared with Tc-MAG3. To conclude Tc-L,L-EC is a useful radiotracer for the evaluation of children with PUJ obstruction, with better assessment of drainage and lower hepatic uptake compared with Tc-MAG3.

Для цитирования: Jain Vishesh, Arora Saurabh, Passah Averilicia, Mani Kalaivani, Yadav Devendra K, Goel Prabudh, Gupta Devendra K. Comparison of the renal dynamic scan performed with 99mTc-L,L-EC and 99mTc-MAG3 in children with pelviureteric junction obstruction.. Nuclear medicine communications. 2018. DOI: 10.1097/mnm.0000000000000902.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.