MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1537-2995.2012.03574.x

Медицинская библиотека · Transfusion · 2012

ABO antibody titers are not predictive of hemolytic reactions due to plasma-incompatible platelet transfusions.

Karafin Matthew S, Blagg Lorraine, Tobian Aaron A R, King Karen E, Ness Paul M, Savage William J

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The overall risk of hemolytic transfusion reactions (HTRs) from plasma (minor)-incompatible platelet (PLT) transfusions and the role of a critical anti-A or anti-B titer in predicting and preventing these reactions has not been clearly established.

STUDY DESIGN AND

METHODS

We evaluated all apheresis PLT (AP) transfusions for 3 months. Using the gel titer method, we determined the anti-A and/or the anti-B immunoglobulin (Ig)G titer for all incompatible APs. Reported febrile transfusion reactions and HTRs were recorded; transfusions were not prospectively evaluated by the study team. A posttransfusion direct antiglobulin test (DAT) and eluate were performed after a reported febrile or hemolytic reaction for patients who received plasma-incompatible APs.

RESULTS

A total of 647 of 4288 AP transfusions (15.1%) were plasma incompatible. Group O APs (n = 278) had significantly higher anti-A and anti-B titers than group A or B APs (p < 0.0001). No group A or B APs had a titer of more than 128 (0/342). For group O APs, 73 had titers of 256 or greater (26.3%), and 27 had titers of 512 or greater (9.7%). No HTRs were reported to any plasma-incompatible AP transfusion during the study period. Two plasma-incompatible AP transfusions were associated with fever and chills and positive DATs, of which one had a positive eluate. The incidence of a DAT and eluate-positive febrile transfusion reaction in the plasma-incompatible AP population is 0.15% (95% confidence interval, 0.0%-0.86%).

CONCLUSION

A critical anti-A or -B titer is not sufficient to predict the risk of hemolysis in patients receiving plasma-incompatible APs, although underreporting of reactions to the blood bank may limit the generalizability of this study.

Для цитирования: Karafin Matthew S, Blagg Lorraine, Tobian Aaron A R, King Karen E, Ness Paul M, Savage William J. ABO antibody titers are not predictive of hemolytic reactions due to plasma-incompatible platelet transfusions.. Transfusion. 2012. DOI: 10.1111/j.1537-2995.2012.03574.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.