m+Medelevator.RU
← Поиск публикаций
PloS one · 2016

Pre- and Postcycloplegic Refractions in Children and Adolescents.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zhu Dan, Wang Yan, Yang Xianrong, Yang Dayong, Guo Kai, Guo Yuanyuan, Jing Xinxia, Pan Chen-Wei

Аннотация

PURPOSE: To determine the difference between cycloplegic and non-cycloplegic refractive error and its associated factors in Chinese children and adolescents with a high prevalence of myopia.

METHODS: A school-based study including 1565 students aged 6 to 21 years was conducted in 2013 in Ejina, Inner Mongolia, China. Comprehensive eye examinations were performed. Pre-and postcycloplegic refractive error were measured using an auto-refractor. For cycloplegic refraction, one drop of topical 1.0% cyclopentolate was administered to each eye twice with a 5-minute interval and a third drop was administered 15 minutes after the second drop if the pupil size was less than 6 mm or if the pupillary light reflex was still present.

RESULTS: Two drops of cyclopentolate were found to be sufficient in 59% of the study participants while the other 41% need an additional drop. The prevalence of myopia was 89.5% in participants aged over 12 years and 68.6% in those aged 12 years or younger (P<0.001). When myopia was defined as spherical equivalent (SE) of less than -0.5 diopter (D), the prevalence estimates were 76.7% (95% confidence interval [CI] 74.6-78.8) and 54.1% (95%CI 51.6-56.6) before and after cycloplegic refraction, respectively. When hyperopia was defined as SE of more than 0.5D, the prevalence was only 2.8% (95%CI 1.9-3.6) before cycloplegic refraction while it was 15.5% (95%CI 13.7-17.3) after cycloplegic refraction. Increased difference between cycloplegic and non-cycloplegic refractive error was associated with decreased intraocular pressures (P = 0.01).

CONCLUSIONS: Lack of cycloplegia in refractive error measurement was associated with significant misclassifications in both myopia and hyperopia among Chinese children and adolescents. Decreased intraocular pressure was related to a greater difference between cycloplegic and non-cycloplegic refractive error.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты