MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-017-2651-9

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2017

Intraoperative blood pressure changes during cemented versus uncemented bipolar hemiarthroplasty for displaced femoral neck fracture: a multi-center cohort study : The effect of bone cement for bipolar hemiarthroplasty in elderly patients.

Miyamoto Shuichi, Nakamura Junichi, Iida Satoshi, Shigemura Tomonori, Kishida Shunji, Abe Isao, Takeshita Munenori, Harada Yoshitada, Orita Sumihisa, Ohtori Seiji

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

INTRODUCTION

The purpose of this study was to compare the cemented bipolar hemiarthroplasty with uncemented about the change of intraoperative blood pressure and the incidence of major complications in elderly patients with femoral neck fracture.

MATERIALS AND

METHODS

This multiple center prospective cohort study included only patients with acute displaced femoral neck fracture (Garden stage III or IV). All patients were treated with cemented or uncemented bipolar hemiarthroplasty using modified Hardinge or Watson-Jones approach in the lateral decubitus position. Baseline data, medical history, type of anesthesia, FiO2 value, the number of vasopressor using during operation, femoral component, intraoperative blood pressure, SaO2, and major complications were evaluated.

RESULTS

Of 164 patients (45 males and 119 females), 86 underwent cemented and 78 underwent uncemented bipolar hemiarthroplasty. Baseline medical histories were similar in both groups. In both the cemented and uncemented groups, intraoperative systolic blood pressure significantly decreased during cementing or rasping (106.3 and 103.6 mmHg) and after femoral component insertion (103.3 and 99.1 mmHg) compared to before rasping (120.7 and 116.4 mmHg) (p < 0.0001, respectively). Donaldson's grade seemed more favorable in uncemented group than in cemented group during cementing or rasping, during stem insertion; however, no patients experienced the lethal complication in both groups.

CONCLUSIONS

Intraoperative blood pressure did not change during cemented and uncemented bipolar hemiarthrplasty for displaced femoral neck fracture. If the standard modern cement technique was performed during operation, bone cement is a safe and acceptable for elderly patients who have a lot of medical histories.

Для цитирования: Miyamoto Shuichi, Nakamura Junichi, Iida Satoshi, Shigemura Tomonori, Kishida Shunji, Abe Isao, Takeshita Munenori, Harada Yoshitada, Orita Sumihisa, Ohtori Seiji. Intraoperative blood pressure changes during cemented versus uncemented bipolar hemiarthroplasty for displaced femoral neck fracture: a multi-center cohort study : The effect of bone cement for bipolar hemiarthroplasty in elderly patients.. Archives of orthopaedic and trauma surgery. 2017. DOI: 10.1007/s00402-017-2651-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.