Intracavitary electron radiotherapy with dynamic shielding for rectal cancer: applicator design and dosimetric characterization.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wang Jinghui, Wang Mingqing, Wang Heming, Lv Jianfeng, Liu Bin, Li Qiheng, Li Dongna, Fu Da, Wang Kai, Fu Dongpo, Du Hanxiang, Xia Xin, Ma Bo, Ran Chaohui, Yan Wenbing, Gai Wei, Zhu Kun, Wang Hao, Yan Xueqing

Аннотация

Objective.Intensity-modulated brachytherapy can improve dose conformity for rectal cancer, but current192Ir-based systems are limited by isotropic photon emission, sequential shield motion, treatment-time penalties, and radioisotope logistics. This study designed, optimized, and characterized a dynamically shielded applicator-based intracavitary electron radiotherapy system intended to improve dose localization and enable ultra-high dose-rate (HDR) delivery without a radioactive source.Approach.A cylindrical electron-beam applicator was designed with a high-density shield containing an emission window, a low-Zscatterer, and a polycarbonate guide tube. Applicator geometry was optimized using TOPAS Monte Carlo simulations to minimize radial and distal transmission factors (TFradialand TFdistal). Dosimetric performance was benchmarked against a modified Monte Carlo model based on a commercial192Ir shielded rectal applicator (Varian GM11004160). A 3D-printed prototype with a stainless-steel shield and resin components was experimentally evaluated using a custom linear accelerator (5 MeV nominal energy, 60 mA peak current, 4μs pulse width). Dose distributions were measured with EBT-XD radiochromic film.Main results.In the modeled homogeneous benchmark geometry, the optimized tungsten applicator achieved a radial transmission factor of approximately 1% at 10 mm from the applicator surface, compared with approximately 20% for the modeled192Ir reference system. Distal leakage remained below 5% beyond the applicator distal end. Under modeled accelerator conditions, the electron-beam system reached approximately 100 Gy s-1at 100 Hz. Superposition of single-dwell dose kernels produced both uniform fields and spatially fractionated radiotherapy patterns with valley-to-peak dose ratios ⩽ 0.2. Prototype measurements demonstrated localized directional dose delivery and ultra-high mean dose rates under the reported pulse conditions, while identifying leakage pathways that caused order-of-magnitude differences from simulation.Significance.The optimized Monte Carlo model demonstrated improved radial dose localization,radioisotope-free operation, and ultra-HDR capability in homogeneous geometry. Further work is needed for accelerator integration, motion control, inverse planning, and validation in anatomically realistic settings.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты