MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/ryct.250138

Медицинская библиотека · Radiology. Cardiothoracic imaging · 2026

Deep Learning Automated Measurement of Shunt Severity with Estimation of Uncertainty in 4D Flow MRI.

Yeluru Akhilesh R R, Tycko Arielle, Cazares Noe, Masutani Evan M, Sankaran Roshun R, Rushworth Parker M, Hall Kent M, Sung Lily, Hsiao Albert

СтатьяПеревод в очереди

Аннотация

Purpose To assess the feasibility of a deep learning (DL) system to fully automate systemic and pulmonary blood flow measurement with four-dimensional (4D) flow MRI. Materials and Methods A total of 188 clinical 4D flow MRI examinations were retrospectively collected to develop a DL system that serially performs (a) three-dimensional localization and (b) two-dimensional segmentation to compute net aortic and pulmonary artery flow. For each vessel, the system computes the means and SDs (σ) across multiple locations. In a separate composite population of 71 patients with and without shunts, automated and manual measurements from trained physicians were compared with ground truth measurements from a senior radiologist using Pearson correlation and Bland-Altman analysis. Results Automated aortic and pulmonary artery flow estimates and shunt fraction calculations were performed in all 71 patients. Correlation with ground truth was strong (ρ = 0.832, 0.863, and 0.861, respectively; P < .001) with low mean bias (0.40 L/min, 0.20 L/min, and -0.10). High certainty (σ < 0.5 L/min) was observed in 83% (59 of 71) of aortic, 75% (53 of 71) of pulmonary, and 65% (46 of 71) of both aortic and pulmonary flow measurements. Within these subsets, correlations improved (ρ = 0.881, 0.989, and 0.948; P < .001) and closely matched expert readers. Conclusion A DL system can automatically measure blood flow from 4D flow MRI with accuracy comparable to that of trained physicians. Keywords: Deep Learning, Congenital Heart Disease, Shunt Severity, 4D Flow MRI, Convolutional Neural Networks Supplemental material is available for this article. © RSNA, 2026.

Для цитирования: Yeluru Akhilesh R R, Tycko Arielle, Cazares Noe, Masutani Evan M, Sankaran Roshun R, Rushworth Parker M, Hall Kent M, Sung Lily, Hsiao Albert. Deep Learning Automated Measurement of Shunt Severity with Estimation of Uncertainty in 4D Flow MRI.. Radiology. Cardiothoracic imaging. 2026. DOI: 10.1148/ryct.250138.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.