DOI 10.2463/mrms.mp.2016-0098

Медицинская библиотека · Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2017

Additive Value of 3T 3D CISS Imaging to Conventional MRI for Assessing the Abnormal Vessels of Spinal Dural Arteriovenous Fistulae.

Uetani Hiroyuki, Hirai Toshinori, Kitajima Mika, Azuma Minako, Yano Shigetoshi, Nakamura Hideo, Makino Keishi, Kai Yutaka, Nagayama Yasunori, Kadota Yoshihito, Yamashita Yasuyuki

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

We investigated the additive value of the 3T 3D constructive interference in steady state (CISS) sequence to conventional MRI for the evaluation of spinal dural arteriovenous fistulae (SDAVF).

MATERIALS AND

METHODS

We included 16 consecutive patients (15 men, 1 woman; age range 42-81 years; mean 64 years) with SDAVF who underwent 3T MRI and digital subtraction angiography (DSA) before treatment. Two neuroradiologists independently evaluated the presence of abnormal vessels on 3D CISS-, T2- and T1-weighted images (T1WI, T2WI), and contrast-enhanced T1WI using a 3-point grading system. Interobserver agreement was assessed by calculating the κ coefficient.

RESULTS

The SDAVF site was the cervical region in one patient, the thoracic region in 12 patients, the lumbar region in two, and the sacral region in one. For the visualization of abnormal vessels, the mean score was significantly higher for 3D CISS than the other sequences (P < 0.05). In 12 of 16 cases (75%) both readers made definite positive findings on additional 3D-CISS images. Interobserver agreement was excellent for 3D CISS images (κ = 1.0), good for T1WI (κ = 0.78; 95% confidence interval [CI] 0.54-1.00) and T2WI (κ = 0.74; 95% CI 0.48-1.00) and moderate for contrast-enhanced T1WI (CET1WI) (κ = 0.50; 95% CI 0.21-0.80).

CONCLUSION

For the assessment of abnormal vessels of SDAVF, the 3T 3D CISS sequence adds value to conventional MRI.

Для цитирования: Uetani Hiroyuki, Hirai Toshinori, Kitajima Mika, Azuma Minako, Yano Shigetoshi, Nakamura Hideo, Makino Keishi, Kai Yutaka, Nagayama Yasunori, Kadota Yoshihito, Yamashita Yasuyuki. Additive Value of 3T 3D CISS Imaging to Conventional MRI for Assessing the Abnormal Vessels of Spinal Dural Arteriovenous Fistulae.. Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine. 2017. DOI: 10.2463/mrms.mp.2016-0098.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.