MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2021.109675

Медицинская библиотека · European journal of radiology · 2021

Optimal end-systolic cardiac phase prediction for low-dose ECG-synchronized cardiac CT.

Goo Hyun Woo

СтатьяПеревод в очереди

Аннотация

PURPOSE: To predict optimal end-systolic (ES) cardiac phase for low-dose ECG-synchronized cardiac computed tomography (CT).

MATERIALS AND

METHODS

ECG-synchronized ES cardiac CT examinations of 2441 patients from September 2010 to December 2016 were reviewed. Of them, 891 examinations acquired with an extended period of full tube current in a cardiac cycle (i.e., 10 % of RR interval or ≥100 ms) and adequate image quality (median patient age, 7 years; age range, 0 day‒60 years) were included. Absolute and relative delays (n = 861 and n = 30, respectively) of the cardiac CT were correlated with the heart rates. Best-fit equations were developed from the trend line with the highest coefficient of determination (R2) value for the two delays, and their success rates to obtain optimal ES phase in a padding with full tube current were calculated and compared with that of the T wave location method. CT radiation dose ratio was calculated as a width ratio of paddings with full tube current.

RESULTS

The absolute and relative delays in the Pearson correlation test demonstrated a strong negative correlation (R = -0.9, p < 0.001) and a nearly moderate positive correlation (R = 0.5, p < 0.001) with heart rates, respectively. Two best-fit equations could be developed separately for both relative (R2 = 0.3) and absolute delays (R2 = 0.8). When adjusting the period of full tube current to a 114 ms for absolute delay and a 17.4 % of RR interval for relative delay, success rates of 94.9 % and 95.1 %, respectively, could be achieved and were significantly higher than that determined by the T wave location (82.7 %, p <  0.001).

CONCLUSION

The best-fit equations method has a higher success rate for predicting the optimal end-systolic phase of ECG-synchronized cardiac CT than the T wave location method.

Для цитирования: Goo Hyun Woo. Optimal end-systolic cardiac phase prediction for low-dose ECG-synchronized cardiac CT.. European journal of radiology. 2021. DOI: 10.1016/j.ejrad.2021.109675.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.