DOI 10.1097/iop.0b013e31829d02ab
Use of x-ray film implant for the repair of orbital fractures.
Аннотация
PURPOSE: To evaluate the experience with sterilized x-ray film in the repair of orbital blow-out fractures (BOFs).
METHODS
A retrospective review of case notes from 56 patients with orbital BOF repaired using sterilized x-ray film onlay implants at 2 institutions between November 2004 and December 2010. Patient demographics, timing of surgery, surgical approach, postoperative complications, and length of follow up were recorded.
RESULTS
Fifty-six patients (44 men, 12 women) received sterilized x-ray film implants during the 6-year study period. Mean age at the time of repair was 29 years (range 4-85 years). For 68% of patients, surgical repair was performed within 2 weeks of injury. Average length of postoperative follow up was 5.5 months (range 1-36 months), 48% had follow up >3 months. Following surgical repair, diplopia in primary or down gaze reduced from 98% to 4% and enophthalmos ≥2 mm reduced from 21% to 5% cases. One patient required a second operation for repositioning of an incompletely reduced fracture. A second patient presented 9 months postoperatively with recurrent episodes of proptosis, and the implant and its surrounding pseudocapsule were subsequently removed. There were no cases of visual loss, implant infection, or migration.
CONCLUSIONS
This series has demonstrated that in selected orbital fractures sterilized x-ray film can provide a safe, effective, and low-cost onlay implant.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.