MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00392-010-0252-5

Медицинская библиотека · Clinical research in cardiology : official journal of the German Cardiac Society · 2010

Time course of right ventricular functional parameters after surgical correction of tetralogy of Fallot determined by cardiac magnetic resonance.

Grothoff M, Hoffmann J, Lehmkuhl L, Abdul-Khaliq H, Nitzsche S, Mahler A, Dähnert I, Berger F, Gutberlet M

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIM: To evaluate changes of right ventricular (RV) parameters in follow-up examinations after corrected tetralogy of Fallot (TOF) by cardiac magnetic resonance (CMR).

METHODS

CMR was performed twice within 4 years in 45 patients using a 1.5 T scanner. RV-volumes and pulmonary-regurgitant-fractions (PRF) were calculated from standard cine-sequences and flow-sensitive gradient-echo images, respectively. Patients were divided into two groups depending on the post-operative (po) interval (group 1 ≤5 years po; group 2 >5 years po) and subgroups depending on type of surgery (transannular vs. non-transannular). Patient groups were compared among each other and differences between 1st and 2nd CMR were assessed. Furthermore, patients were compared with 25 healthy volunteers.

RESULTS

Compared with controls RV-size was increased (group 1: p = 0.007; group 2: p < 0.001) and RV function decreased (group 1: p = 0.02; group 2: p < 0.001) in po TOF-patients. PRF was higher in group 2 compared with group 1 (p = 0.04) and significant changes of PRF between 1st and 2nd CMR were found in group 2 (p < 0.01), but not in group 1 (p = 0.29). Compared with the non-transannular subgroup, PRF (p < 0.001) and RV end-diastolic-volume index (RV-EDVI) (p = 0.03) were significantly higher in patients with a transannular patch, EDVI increased between 1st and 2nd CMR. After correction, no significant changes of RV myocardial mass index (RV-MMI) were found.

CONCLUSION

After correction of TOF, RV-size, RV-muscle mass (RV-MM) was increased and ejection fraction decreased in "early" follow-up already. Whereas these parameters can remain stable over a long time period, the PRF significantly increased in "late" follow-up dependent on the po interval. Overall, transannular patching went along with higher PRF and bigger RV-size as well as a greater dynamic of these parameters in the time course, which makes this subgroup highly in need of regular follow-up examinations for the optimal timing of re-interventions. In contrast, the increased RV-MM demonstrated no regression po.

Для цитирования: Grothoff M, Hoffmann J, Lehmkuhl L, Abdul-Khaliq H, Nitzsche S, Mahler A, Dähnert I, Berger F, Gutberlet M. Time course of right ventricular functional parameters after surgical correction of tetralogy of Fallot determined by cardiac magnetic resonance.. Clinical research in cardiology : official journal of the German Cardiac Society. 2010. DOI: 10.1007/s00392-010-0252-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.