Cardiac output assessed by arterial thermodilution during exsanguination and fluid resuscitation: experimental validation against a reference technique.

Friedman Z, Berkenstadt H, Margalit N, Sega E, Perel A

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVE

The arterial thermodilution technique offers the ability to measure cardiac output using only central venous and arterial catheters. However, the technique has been reported to overestimate cardiac output because of a higher loss of cold indicator due to the increased distance between the sites of injection and measurement. In this study, the two techniques were compared with respect to conditions of low cardiac output in which a longer passage time may further increase loss of indicator.

METHODS

Seventeen anaesthetized dogs were studied during hypovolaemic shock and fluid resuscitation. Cardiac output measurements were carried out simultaneously by arterial and pulmonary artery thermodilution techniques.

RESULTS

One-hundred-and-two measurements were performed. The mean cardiac output was 2.28 +/- 1.4Lmin(-1) by the pulmonary arterial technique and 2.29 +/- 1.56Lmin(-1) by the arterial thermodilution technique. The correlation coefficient between the two measurements was 0.95, the precision -0.04 +/- 0.41 Lmin(-1) and the limits of agreement from -0.86 to 0.78Lmin(-1). The agreement was also consistent at low cardiac outputs.

CONCLUSIONS

The arterial thermodilution technique may serve as a less invasive cardiac output monitor in conditions of severe bleeding and shock.

Для цитирования: Friedman Z, Berkenstadt H, Margalit N, Sega E, Perel A. Cardiac output assessed by arterial thermodilution during exsanguination and fluid resuscitation: experimental validation against a reference technique.. European journal of anaesthesiology. 2002. DOI: 10.1017/s0265021502000546.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.