MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0033-1359718

Медицинская библиотека · American journal of perinatology · 2013

The timing of adverse events with Foley catheter preinduction cervical ripening; implications for outpatient use.

Sciscione Anthony C, Bedder Casey L, Hoffman Matthew K, Ruhstaller Kelly, Shlossman Phillip A

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

We sought to determine the rate and timing of adverse events that occur during preinduction cervical ripening using the Foley catheter before extrusion of the balloon and institution of oxytocin.

STUDY

DESIGN

Using electronic medical records, we identified all women who presented for preinduction cervical ripening using a Foley catheter with a term (≥37 weeks) singleton vertex live fetus from January 1, 2006, to June 14, 2009. Women were excluded if they had had a previous cesarean delivery, gestational hypertension or preeclampsia, pregestational diabetes, rupture of membranes before induction, fetal anomaly, or antepartum stillbirth. Outcomes were cesarean delivery for nonreassuring fetal tracing, vaginal bleeding, placental abruption, or intrapartum stillbirth occurring between 2 hours after Foley catheter placement and 6 am.

RESULTS

Among 2,514 women, 1,905 met the inclusion criteria. No adverse outcomes were noted among term, singleton uncomplicated pregnancies receiving a Foley catheter for preinduction cervical ripening who met inclusion criteria (relative risk, 0.0; 95% confidence interval, 0.0-0.002).

CONCLUSIONS

In a low-risk population, the use of the Foley catheter for preinduction cervical ripening was associated with no adverse outcomes. It appears to be a safe mechanism for cervical ripening and has the potential for use in the outpatient setting in a selected subset of women.

Для цитирования: Sciscione Anthony C, Bedder Casey L, Hoffman Matthew K, Ruhstaller Kelly, Shlossman Phillip A. The timing of adverse events with Foley catheter preinduction cervical ripening; implications for outpatient use.. American journal of perinatology. 2013. DOI: 10.1055/s-0033-1359718.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.