MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00247-026-06668-1

Медицинская библиотека · Pediatric radiology · 2026

Super-resolution deep learning reconstruction achieves low-dose high-resolution imaging in pediatric cardiac computed tomography.

Obinata Haruka, Takigiku Kiyohiro, Yonehara Kosuke, Shibuya Yuma, Akazawa Yohei, Takei Kohta, Miyazawa Daisuke, Sakashita Taro

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Cardiac computed tomography (CT) is widely utilized in pediatric cardiology, but minimizing radiation exposure is essential. Recently, super-resolution deep learning reconstruction (SR-DLR) has emerged as a potential advancement over conventional deep learning reconstruction (C-DLR).

OBJECTIVE

To evaluate the potential of SR-DLR for further radiation dose reduction in pediatric cardiac CT through a comparison with C-DLR.

MATERIALS AND

METHODS

The phantom-based study assessed noise power spectrum and spatial resolution. For the clinical study, we compared nine C-DLR images (conventional radiation dose) and 11 SR-DLR images (lower radiation dose). Evaluation metrics included noise levels, contrast-to-noise ratio, and edge rise distance and edge rise slope.

RESULTS

In the phantom-based study, SR-DLR (250 mA) displayed equivalent noise characteristics as C-DLR (800 mA) while achieving superior spatial resolution. In clinical images, preliminary comparisons within the high-dose group revealed that SR-DLR significantly outperformed C-DLR in spatial resolution metrics, specifically edge rise distance and edge rise slope (P<0.001). Furthermore, despite the lower radiation dose used for SR-DLR than for C-DLR (volume CT dose index, 4.25±0.54 mGy vs. 13.3±6.43 mGy), there were no significant differences in noise, contrast resolution, and spatial resolution between the groups.

CONCLUSION

SR-DLR maintains non-inferior image quality compared with C-DLR even at reduced radiation doses. These findings substantiate the potential for further dose reduction in pediatric cardiac CT without compromising image quality.

Для цитирования: Obinata Haruka, Takigiku Kiyohiro, Yonehara Kosuke, Shibuya Yuma, Akazawa Yohei, Takei Kohta, Miyazawa Daisuke, Sakashita Taro. Super-resolution deep learning reconstruction achieves low-dose high-resolution imaging in pediatric cardiac computed tomography.. Pediatric radiology. 2026. DOI: 10.1007/s00247-026-06668-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.