MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jpurol.2016.08.027

Медицинская библиотека · Journal of pediatric urology · 2016

Laparoscopic pyeloplasty: Initial experience with 3D vision laparoscopy and articulating shears.

Abou-Haidar Hiba, Al-Qaoud Talal, Jednak Roman, Brzezinski Alex, El-Sherbiny Mohamed, Capolicchio John-Paul

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

INTRODUCTION

Laparoscopic reconstructive surgery is associated with a steep learning curve related to the use of two-dimensional (2D) vision and rigid instruments. With the advent of robotic surgery, three-dimensional (3D) vision, and articulated instruments, this learning curve has been facilitated. We present a hybrid alternative to robotic surgery, using laparoscopy with 3D vision and articulated shears.

OBJECTIVE

To compare outcomes of children undergoing pyeloplasty using 3D laparoscopy with articulated instruments with those undergoing the same surgery using standard laparoscopy with 2D vision and rigid instruments.

STUDY

DESIGN

Medical charts of 33 consecutive patients with ureteropelvic junction obstruction who underwent laparoscopic pyeloplasty by a single surgeon from 2006 to 2013 were reviewed in a retrospective manner. The current 3D cohort was compared with the previous 2D cohort. Data on age, weight, gender, side, operative time, dimension (2D = 19 patients, 3D = 8 patients), presence of a crossing vessel, length of hospital stay, and complication rate were compared between the two groups. Articulating shears were used for pelvotomy and spatulation of the ureter in the 3D group. Statistical tests included linear regression models and chi square tests for trends using STATA software.

RESULTS

Operative time per case was decreased by an average of 48 min in the group undergoing 3D laparoscopic pyeloplasty compared with the group undergoing 2D laparoscopic pyeloplasty (p = 0.02) (Figure). Complication rate and length of hospital stay were not significantly affected by the use of 3D laparoscopy.

DISCUSSION: These favorable results are in accordance with previous literature emphasizing the importance of 3D vision in faster and more precise execution of complex surgical maneuvers. The use of flexible instruments has also helped overcome the well-described delicate step of a dismembered pyeloplasty, namely the pelvotomy and ureteral spatulation. Limitations of this study are those inherent to the retrospective study design.

CONCLUSION

The use of 3D vision endoscopy with articulating instruments blurs the distinction between current robotic-assisted and conventional laparoscopic technology, and provides a hybrid alternative deserving further attention.

Для цитирования: Abou-Haidar Hiba, Al-Qaoud Talal, Jednak Roman, Brzezinski Alex, El-Sherbiny Mohamed, Capolicchio John-Paul. Laparoscopic pyeloplasty: Initial experience with 3D vision laparoscopy and articulating shears.. Journal of pediatric urology. 2016. DOI: 10.1016/j.jpurol.2016.08.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.