MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0340649

Медицинская библиотека · PloS one · 2026

Performance of glomerular filtration rate equations using serum creatinine in children with congenital anomalies of the kidney and urinary tract.

Marpaung Ferdy Royland, Purnami Santi Wulan, Andari Shofi, Rohman Ali, Notobroto Hari Basuki, Prasetyo Risky Vitria, Lumban Toruan Anggia Augustasia, Santoso Djoko, Aryati Aryati

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

INTRODUCTION

Congenital anomalies of the kidney and urinary tract (CAKUT) are a significant cause of pediatric morbidity and mortality, often leading to chronic kidney disease (CKD). Accurate glomerular filtration rate (GFR) assessment is crucial for effective management, but a gold-standard pediatric GFR estimation formula remains elusive. This study compared the bedside Schwartz, Chronic Kidney Disease in Children (CKiD-U25) creatinine, and European Kidney Function Consortium (EKFC) creatinine-based equations against measured GFR (mGFR) using technetium-99m-diethylenetriaminepentaacetic acid (Tc-99mDTPA) clearance.

METHODS

Data were collected from 276 children with CAKUT at Dr. Soetomo Academic General Hospital. Estimated GFR (eGFR) was calculated using the bedside Schwartz, CKiD-U25, and EKFC equations. mGFR was determined using Tc-99mDTPA clearance, considered the gold standard. Correlation (Spearman rs), bias, and accuracy (P30, percentage of eGFR within 30% of mGFR) were assessed. Subgroup analysis was performed for children older than two years.

RESULTS

Both equations correlated significantly with mGFR (bedside Schwartz: r = 0.793; CKiD-U25: r = 0,793; EKFC: r = 0.745, p < 0.0001). However, the bedside Schwartz systematically underestimated mGFR (bias: -21.7 mL/min/1.73 m²), while the EKFC overestimated (bias: 17 mL/min/1.73 m², p < 0.0001). In children >2 years, correlations strengthened (bedside Schwartz: r = 0.804; EKFC: r = 0.835, p < 0.0001), with the EKFC demonstrating more accuracy (P30: 90.1%) compared to the bedside Schwartz CKiD-U25 creatinine (75% and 75%, respectively).

CONCLUSION

These findings suggest the both bedside Schwartz and EKFC could be a reliable tool for GFR estimation in this pediatric CAKUT population.

Для цитирования: Marpaung Ferdy Royland, Purnami Santi Wulan, Andari Shofi, Rohman Ali, Notobroto Hari Basuki, Prasetyo Risky Vitria, Lumban Toruan Anggia Augustasia, Santoso Djoko, Aryati Aryati. Performance of glomerular filtration rate equations using serum creatinine in children with congenital anomalies of the kidney and urinary tract.. PloS one. 2026. DOI: 10.1371/journal.pone.0340649.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.