MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10047-018-1039-0

Медицинская библиотека · Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2018

Anatomical study of the Cleveland Clinic continuous-flow total artificial heart in adult and pediatric configurations.

Fukamachi Kiyotaka, Karimov Jamshid H, Byram Nicole A, Sunagawa Gengo, Dessoffy Raymond, Miyamoto Takuma, Horvath David J

СтатьяПеревод в очереди

Аннотация

The purpose of this study was to assess the smallest possible body sizes of patients in whom the Cleveland Clinic continuous-flow total artificial heart for adult (CFTAH) and pediatric configurations (P-CFTAH) can fit. One of the most critical dimensions is the vertebra-to-sternum distance at the junction of the right atrium to the inferior vena cava (V-S distance). Our previous CFTAH anatomical fitting study suggested that the CFTAH would fit patients of V-S distance ≥ 7.5 cm and the P-CFTAH of V-S distance ≥ 5.25 cm (70% of 7.5 cm). To confirm this, we assessed the relationship between body surface area (BSA) and V-S distance in 15 adult patients (BSA 1.86-2.62 m2) and 31 pediatric patients (BSA 0.17-1.80 m2) whose computed tomography scans were available. We found a highly significant correlation between BSA and V-S distance (p < 1.0 × 10-25). It appears that the CFTAH will fit in most patients with BSA ≥ 1.0 m2 (corresponding height of ≥ 130 cm and age of 9 years) and the P-CFTAH in patients with BSA ≥ 0.3 m2 (corresponding height of ≥ 55 cm and age of 1 month). Further anatomical fitting studies are needed to evaluate the two pump models inside human chests to determine the smallest patient size/critical dimensions and device port configurations.

Для цитирования: Fukamachi Kiyotaka, Karimov Jamshid H, Byram Nicole A, Sunagawa Gengo, Dessoffy Raymond, Miyamoto Takuma, Horvath David J. Anatomical study of the Cleveland Clinic continuous-flow total artificial heart in adult and pediatric configurations.. Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs. 2018. DOI: 10.1007/s10047-018-1039-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.